This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.231W
68.145%
0.033
5.122V
0.339W
115.16V
2
0.09A
0.461W
73.64%
0.061
5.121V
0.626W
115.16V
3
0.55A
2.807W
80.719%
0.262
5.103V
3.477W
115.17V
4
1A
5.087W
80.799%
0.358
5.085V
6.295W
115.17V
5
1.5A
7.604W
81.047%
0.413
5.068V
9.382W
115.17V
6
2.501A
12.599W
80.37%
0.467
5.038V
15.676W
115.16V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.231W
58.552%
0.012
5.12V
0.395W
230.37V
2
0.09A
0.461W
68.924%
0.02
5.119V
0.669W
230.36V
3
0.55A
2.805W
79.146%
0.102
5.098V
3.544W
230.34V
4
1A
5.079W
80.364%
0.171
5.078V
6.32W
230.32V
5
1.5A
7.585W
80.675%
0.238
5.056V
9.402W
230.27V
6
2.501A
12.54W
80.973%
0.319
5.015V
15.486W
230.31V
Supplementary Tests (For Reference)
Typical Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Temps (In/Out)
PF/AC Volts
10%
3.988A
1.96A
1.973A
1.008A
70.006
89.185%
45.37°C
0.957
12.137V
5.104V
3.346V
4.96V
78.495
40.36°C
115.2V
20%
8.990A
2.948A
2.976A
1.216A
139.962
92.251%
46.16°C
0.984
12.131V
5.09V
3.327V
4.935V
151.718
40.57°C
115.19V
30%
14.348A
3.447A
3.485A
1.426A
210.01
92.829%
47.57°C
0.989
12.124V
5.078V
3.314V
4.91V
226.233
41.35°C
115.21V
40%
19.711A
3.949A
4A
1.637A
280.06
92.973%
48.71°C
0.992
12.117V
5.066V
3.3V
4.887V
301.226
42.15°C
115.18V
50%
24.730A
4.95A
5.031A
1.851A
350.02
92.916%
49.31°C
0.997
12.111V
5.052V
3.28V
4.862V
376.703
42.35°C
115.17V
60%
29.759A
5.957A
6.075A
2.001A
419.752
92.465%
50.16°C
0.995
12.105V
5.037V
3.26V
4.839V
453.959
42.48°C
115.14V
70%
34.801A
6.971A
7.133A
2.286A
490.204
92.02%
51.28°C
0.995
12.100V
5.022V
3.239V
4.812V
532.715
43.27°C
115.13V
80%
39.846A
7.99A
8.203A
2.4A
559.822
91.624%
52.11°C
0.996
12.095V
5.008V
3.218V
4.792V
610.997
43.49°C
115.15V
90%
45.294A
8.512A
8.744A
2.514A
630.065
91.18%
53.92°C
0.997
12.089V
4.994V
3.202V
4.774V
691.011
44.82°C
115.16V
100%
50.748A
9.038A
9.312A
2.629A
700.4
90.633%
55.54°C
0.997
12.083V
4.98V
3.19V
4.756V
772.786
45.6°C
115.18V
110%
55.806A
10.08A
10.519A
2.638A
769.828
89.989%
57.27°C
0.997
12.078V
4.961V
3.166V
4.739V
855.467
46.61°C
115.18V
CL1
0.115A
11.925A
12.268A
0A
101.318
87.273%
49.7°C
0.975
12.152V
5.049V
3.236V
4.979V
116.094
42.76°C
115.21V
CL2
0.115A
19.859A
0A
0A
101.4
86.567%
51.4°C
0.975
12.152V
5.036V
3.343V
4.997V
117.134
43.77°C
115.21V
CL3
0.115A
0A
20.726A
0A
67.398
80.033%
53.47°C
0.96
12.149V
5.083V
3.184V
4.97V
84.213
44.77°C
115.2V
CL4
57.975A
0A
0A
0A
700.244
91.733%
54.96°C
0.997
12.078V
5.027V
3.295V
4.911V
763.347
45.7°C
115.15V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Temps (In/Out)
PF/AC Volts
10%
4.040A
2A
2A
1A
70.914
90.014%
45.38°C
0.756
12.140V
5.103V
3.346V
4.961V
78.781
40.44°C
230.41V
20%
9.106A
3.001A
3A
1.2A
141.691
93.303%
46.03°C
0.891
12.136V
5.089V
3.328V
4.936V
151.862
40.78°C
230.41V
30%
14.507A
3.501A
3.5A
1.4A
212.262
94.154%
46.81°C
0.938
12.132V
5.077V
3.315V
4.913V
225.442
40.96°C
230.42V
40%
19.908A
4.001A
4A
1.6A
282.765
94.448%
48.17°C
0.959
12.129V
5.066V
3.301V
4.89V
299.387
41.88°C
230.43V
50%
24.966A
5.001A
5.001A
1.8A
353.196
94.412%
49.23°C
0.971
12.126V
5.052V
3.282V
4.866V
374.101
42.29°C
230.42V
60%
30.033A
6.001A
6A
2.001A
423.603
94.22%
50.21°C
0.976
12.124V
5.037V
3.263V
4.842V
449.589
42.79°C
230.44V
70%
35.091A
7.003A
7A
2.201A
493.819
93.967%
51.61°C
0.982
12.121V
5.022V
3.243V
4.82V
525.524
43.65°C
230.44V
80%
39.775A
7.989A
8.199A
2.398A
559.7
93.615%
52.53°C
0.984
12.112V
5.008V
3.22V
4.796V
597.872
44.14°C
230.44V
90%
45.206A
8.512A
8.738A
2.512A
630.023
93.365%
53.84°C
0.987
12.112V
4.994V
3.205V
4.778V
674.794
44.68°C
230.44V
100%
50.637A
9.039A
9.315A
2.627A
700.385
93.045%
55.63°C
0.988
12.109V
4.979V
3.188V
4.759V
752.735
45.55°C
230.44V
110%
55.675A
10.079A
10.516A
2.637A
769.816
92.628%
57.37°C
0.989
12.106V
4.962V
3.166V
4.742V
831.082
46.59°C
230.44V
CL1
0.115A
11.928A
12.269A
0A
101.32
88.016%
49.47°C
0.845
12.150V
5.048V
3.236V
4.976V
115.116
42.53°C
230.42V
CL2
0.115A
19.866A
0A
0A
101.401
87.304%
51.41°C
0.847
12.151V
5.034V
3.342V
4.995V
116.147
43.68°C
230.42V
CL3
0.115A
0A
20.734A
0A
67.397
80.506%
52.69°C
0.769
12.148V
5.082V
3.183V
4.971V
83.716
44.34°C
230.42V
CL4
57.825A
0A
0A
0A
700.245
94.158%
54.87°C
0.988
12.110V
5.027V
3.295V
4.911V
743.69
45.83°C
230.43V
The results above are not used in the certification process
Light Load Tests
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Temps (In/Out)
PF/AC Volts
20W
1.225A
0.489A
0.49A
0.199A
20.005
77.906%
39.83°C
0.802
12.129V
5.117V
3.368V
5.015V
25.678
36.69°C
115.18V
40W
2.696A
0.684A
0.687A
0.3A
40.004
85.782%
40.86°C
0.912
12.127V
5.113V
3.364V
5.005V
46.634
37.21°C
115.16V
60W
4.165A
0.881A
0.884A
0.4A
60.003
88.788%
42.05°C
0.949
12.133V
5.111V
3.359V
4.996V
67.58
37.98°C
115.2V
80W
5.631A
1.077A
1.082A
0.501A
79.964
90.633%
43.56°C
0.964
12.135V
5.108V
3.355V
4.986V
88.228
39.09°C
115.22V
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Temps (In/Out)
PF/AC Volts
20W
1.240A
0.5A
0.5A
0.2A
20.298
78.225%
39.75°C
0.459
12.132V
5.117V
3.368V
5.013V
25.948
36.63°C
230.4V
40W
2.720A
0.7A
0.7A
0.3A
40.442
85.283%
40.94°C
0.626
12.132V
5.114V
3.364V
5.004V
47.421
37.36°C
230.41V
60W
4.224A
0.9A
0.9A
0.4A
60.907
89.848%
42.56°C
0.721
12.140V
5.11V
3.36V
4.996V
67.789
38.54°C
230.42V
80W
5.704A
1.1A
1.1A
0.5A
81.049
91.648%
43.74°C
0.783
12.139V
5.107V
3.355V
4.986V
88.435
39.27°C
230.42V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
15.36mV
7.06mV
5.94mV
7.03mV
Pass
20% Load
16.43mV
7.67mV
6.09mV
7.34mV
Pass
30% Load
17.25mV
8.08mV
6.55mV
8.41mV
Pass
40% Load
10.86mV
8.28mV
6.55mV
8.57mV
Pass
50% Load
13.03mV
9.46mV
9.31mV
16.82mV
Pass
60% Load
12.75mV
10.94mV
7.88mV
9.69mV
Pass
70% Load
14.29mV
11.20mV
9.52mV
10.20mV
Pass
80% Load
15.36mV
11.25mV
15.71mV
9.58mV
Pass
90% Load
16.13mV
11.71mV
14.89mV
9.63mV
Pass
100% Load
23.84mV
12.95mV
16.41mV
11.81mV
Pass
110% Load
25.25mV
13.64mV
17.11mV
12.23mV
Pass
Crossload1
16.85mV
9.46mV
16.37mV
6.06mV
Pass
Crossload2
14.80mV
9.26mV
6.50mV
6.12mV
Pass
Crossload3
14.64mV
9.15mV
20.32mV
6.22mV
Pass
Crossload4
23.95mV
12.12mV
7.56mV
10.83mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
17.45mV
7.06mV
6.09mV
6.88mV
Pass
20% Load
17.71mV
7.57mV
6.09mV
7.44mV
Pass
30% Load
16.94mV
8.23mV
6.35mV
7.80mV
Pass
40% Load
11.17mV
8.69mV
6.70mV
9.02mV
Pass
50% Load
10.25mV
9.21mV
7.27mV
8.72mV
Pass
60% Load
11.17mV
10.64mV
10.44mV
9.28mV
Pass
70% Load
13.16mV
11.46mV
11.77mV
9.58mV
Pass
80% Load
14.90mV
11.81mV
14.84mV
10.91mV
Pass
90% Load
15.46mV
11.61mV
15.30mV
9.33mV
Pass
100% Load
23.20mV
12.02mV
16.10mV
12.24mV
Pass
110% Load
25.52mV
12.78mV
17.56mV
12.42mV
Pass
Crossload1
19.40mV
9.81mV
15.31mV
6.01mV
Pass
Crossload2
16.13mV
9.67mV
6.55mV
5.96mV
Pass
Crossload3
15.25mV
8.74mV
19.75mV
5.76mV
Pass
Crossload4
23.93mV
12.20mV
17.37mV
11.06mV
Pass
The results above are not used in the certification process