Hong Hua HA9215VH12FD-F00 (92mm, 12V, 0.36A, Fluid Dynamic Bearing Fan)
5VSB Circuit
-
Standby PWM Controller
On-Bright OB2365SP
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
Performance Summary
Efficiency Rating
GOLD
Noise Rating
Standard++
Average Efficiency (>1450 load combinations)
88.712%
Average Noise Output (>1450 Load Combinations)
33.08dBA
Average PF (>1450 Load Combinations)
0.972
Efficiency With 10W (≤500W) or 2% (>500W) Load
48.150%
Standby Power Consumption
0.0447W
12V Ripple (Full Load)
13.64mV
5V Ripple (Full Load)
12.07mV
3.3V Ripple (Full Load)
15.05mV
5VSB Ripple (Full Load)
14.49mV
12V Load Regulation
1.10%
5V Load Regulation
1.34%
3.3V Load Regulation
1.90%
5VSB Load Regulation
2.60%
Inrush Current
77.420A
Efficiency Rating
GOLD
Noise Rating
Standard+
Average Efficiency (>1450 load combinations)
90.692%
Average Noise Output (>1450 Load Combinations)
37.19dBA
Average PF (>1450 Load Combinations)
0.930
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.0841W
12V Ripple (Full Load)
14.87mV
5V Ripple (Full Load)
12.60mV
3.3V Ripple (Full Load)
13.75mV
5VSB Ripple (Full Load)
14.35mV
12V Load Regulation
1.03%
5V Load Regulation
1.26%
3.3V Load Regulation
1.84%
5VSB Load Regulation
2.56%
Inrush Current
88.810A
12V Transient Response (150%)
0.00V
5V Transient Response (150%)
V
3.3V Transient Response (150%)
V
5VSB Transient Response (150%)
V
Hold-Up Time & Power Ok Signal
19.60ms
AC Loss to PWR_OK Hold Up Time
16.10ms
PWR_OK Inactive to DC Loss Delay
3.50ms
PSU Timings: T1 (20% / 100%)
50.0ms
50.0ms
PSU Timings: T3 (20% / 100%)
126.0ms
126.0ms
OPP (30.86°C / 43.61°C)
119.36%
117.36%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
19.6
AC Loss to PWR_OK Hold Up Time (ms)
16.1
PWR_OK Inactive to DC Loss Delay (ms)
3.5
Vampire Power
Tables
Graphs
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.231
66.189%
0.039
5.119V
0.349
115.13V
2
0.090A
0.461
72.484%
0.071
5.117V
0.636
115.14V
3
0.550A
2.808
79.255%
0.284
5.105V
3.543
115.13V
4
1.000A
5.094
79.668%
0.373
5.093V
6.394
115.13V
5
1.500A
7.620
79.640%
0.419
5.079V
9.568
115.13V
6
3.000A
15.116
77.363%
0.476
5.038V
19.539
115.14V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.230
58.376%
0.014
5.119V
0.394
230.25V
2
0.090A
0.461
67.496%
0.024
5.117V
0.683
230.26V
3
0.550A
2.808
78.788%
0.115
5.105V
3.564
230.26V
4
1.000A
5.094
79.756%
0.187
5.093V
6.387
230.26V
5
1.500A
7.620
80.135%
0.247
5.080V
9.509
230.26V
6
3.000A
15.118
79.376%
0.348
5.039V
19.046
230.26V
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.580A
1.995A
1.962A
0.983A
64.958
82.715%
2296
38.0
39.71°C
0.908
12.111V
5.010V
3.366V
5.088V
78.532
45.21°C
115.10V
2
8.206A
2.998A
2.945A
1.182A
130.012
87.694%
2435
39.6
40.56°C
0.952
12.079V
5.003V
3.359V
5.077V
148.256
46.63°C
115.10V
3
13.173A
3.501A
3.446A
1.381A
195.018
89.422%
2545
41.2
41.48°C
0.958
12.068V
4.997V
3.353V
5.067V
218.087
48.24°C
115.11V
4
18.150A
4.007A
3.945A
1.582A
260.033
90.068%
2663
41.9
41.79°C
0.969
12.057V
4.990V
3.347V
5.057V
288.707
48.97°C
115.11V
5
22.795A
5.018A
4.942A
1.784A
325.079
90.145%
2780
42.9
42.04°C
0.977
12.045V
4.983V
3.340V
5.046V
360.616
49.81°C
115.11V
6
27.399A
6.030A
5.942A
1.986A
389.502
89.978%
2855
43.7
42.38°C
0.983
12.033V
4.976V
3.333V
5.035V
432.888
50.97°C
115.11V
7
32.084A
7.046A
6.947A
2.190A
454.833
89.596%
3025
46.7
43.23°C
0.987
12.022V
4.969V
3.326V
5.024V
507.649
52.53°C
115.10V
8
36.780A
8.003A
7.955A
2.395A
519.836
89.078%
3075
46.5
43.99°C
0.989
12.010V
4.961V
3.319V
5.012V
583.572
53.75°C
115.10V
9
41.888A
8.582A
8.451A
2.398A
585.088
88.637%
3076
46.5
44.31°C
0.991
11.998V
4.954V
3.313V
5.005V
660.095
54.67°C
115.10V
10
46.742A
9.100A
8.984A
3.012A
649.924
88.008%
3081
46.5
45.63°C
0.992
11.985V
4.947V
3.306V
4.981V
738.482
56.55°C
115.10V
11
52.212A
9.111A
8.999A
3.015A
714.746
87.406%
3081
46.5
46.91°C
0.992
11.971V
4.940V
3.301V
4.976V
817.727
58.64°C
115.11V
CL1
0.118A
14.003A
13.999A
0.000A
117.975
83.217%
2967
45.3
42.23°C
0.950
12.096V
4.981V
3.343V
5.099V
141.768
49.46°C
115.12V
CL2
54.112A
1.000A
1.001A
1.000A
661.325
88.506%
3082
46.5
45.80°C
0.992
11.975V
4.962V
3.320V
5.049V
747.210
56.13°C
115.10V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.582A
1.996A
1.962A
0.983A
64.973
84.666%
2328
38.3
40.12°C
0.780
12.108V
5.010V
3.365V
5.088V
76.740
45.41°C
230.27V
2
8.210A
2.999A
2.948A
1.182A
130.048
89.848%
2405
39.5
40.73°C
0.872
12.076V
5.003V
3.358V
5.077V
144.742
46.56°C
230.27V
3
13.178A
3.503A
3.445A
1.382A
195.055
91.439%
2554
41.3
41.46°C
0.906
12.065V
4.998V
3.353V
5.067V
213.317
47.84°C
230.26V
4
18.156A
4.008A
3.945A
1.582A
260.060
92.057%
2629
41.3
41.82°C
0.927
12.054V
4.991V
3.347V
5.057V
282.498
48.87°C
230.26V
5
22.803A
5.016A
4.940A
1.784A
325.099
92.267%
2692
42.5
42.15°C
0.937
12.042V
4.985V
3.340V
5.046V
352.345
49.80°C
230.26V
6
27.410A
6.029A
5.942A
1.986A
389.559
92.242%
2800
43.0
42.38°C
0.948
12.030V
4.978V
3.333V
5.035V
422.321
50.71°C
230.25V
7
32.093A
7.044A
6.949A
2.190A
454.858
92.043%
2976
45.6
43.09°C
0.954
12.019V
4.971V
3.326V
5.025V
494.178
51.81°C
230.25V
8
36.790A
8.004A
7.955A
2.395A
519.871
91.764%
3095
46.6
43.64°C
0.959
12.007V
4.963V
3.319V
5.013V
566.533
53.20°C
230.25V
9
41.899A
8.578A
8.452A
2.398A
585.066
91.533%
3099
46.7
44.18°C
0.964
11.994V
4.957V
3.313V
5.007V
639.187
54.14°C
230.25V
10
46.748A
9.094A
8.983A
3.012A
649.901
91.167%
3104
46.9
45.45°C
0.968
11.983V
4.950V
3.306V
4.982V
712.868
56.47°C
230.24V
11
52.214A
9.106A
9.001A
3.015A
714.718
90.869%
3106
46.9
46.79°C
0.970
11.970V
4.943V
3.300V
4.976V
786.538
58.56°C
230.25V
CL1
0.117A
14.004A
13.999A
0.000A
118.039
85.379%
2966
45.3
42.45°C
0.865
12.095V
4.986V
3.343V
5.100V
138.253
49.59°C
230.25V
CL2
54.107A
1.000A
0.999A
1.000A
661.153
91.701%
3103
46.8
45.88°C
0.968
11.973V
4.963V
3.320V
5.050V
720.986
56.52°C
230.25V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.225A
0.498A
0.489A
0.196A
19.986
52.409%
1844
31.7
0.851
12.111V
5.017V
3.372V
5.114V
38.135
115.09V
2
2.450A
0.994A
0.979A
0.392A
39.974
75.889%
2180
36.5
0.878
12.118V
5.014V
3.370V
5.107V
52.674
115.09V
3
3.680A
1.496A
1.468A
0.588A
60.006
82.378%
2142
36.0
0.901
12.111V
5.011V
3.367V
5.099V
72.842
115.10V
4
4.910A
1.997A
1.962A
0.785A
79.957
84.717%
2205
36.7
0.919
12.089V
5.009V
3.364V
5.092V
94.381
115.10V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.226A
0.497A
0.491A
0.196A
19.997
54.611%
1773
30.6
0.617
12.110V
5.016V
3.371V
5.114V
36.617
230.26V
2
2.450A
0.997A
0.981A
0.392A
39.989
78.014%
2045
34.6
0.697
12.116V
5.013V
3.369V
5.107V
51.259
230.26V
3
3.681A
1.497A
1.471A
0.588A
60.020
84.602%
2087
35.3
0.767
12.108V
5.011V
3.366V
5.099V
70.944
230.27V
4
4.912A
1.997A
1.961A
0.786A
79.972
87.106%
2223
36.9
0.808
12.087V
5.008V
3.364V
5.093V
91.810
230.26V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
18.40mV
8.40mV
12.70mV
5.80mV
Pass
20% Load
11.90mV
8.90mV
13.20mV
6.10mV
Pass
30% Load
10.10mV
9.50mV
13.40mV
7.60mV
Pass
40% Load
10.60mV
9.50mV
14.10mV
8.60mV
Pass
50% Load
9.70mV
9.60mV
14.50mV
9.30mV
Pass
60% Load
9.90mV
10.60mV
13.80mV
9.90mV
Pass
70% Load
10.20mV
10.90mV
13.90mV
10.40mV
Pass
80% Load
10.80mV
12.10mV
15.10mV
12.50mV
Pass
90% Load
10.80mV
12.00mV
14.60mV
13.50mV
Pass
100% Load
13.60mV
12.10mV
15.10mV
14.50mV
Pass
110% Load
14.40mV
12.50mV
14.30mV
16.20mV
Pass
Crossload1
17.00mV
9.50mV
12.70mV
6.20mV
Pass
Crossload2
14.00mV
12.40mV
14.60mV
11.10mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
20.60mV
9.60mV
11.30mV
5.80mV
Pass
20% Load
12.60mV
9.20mV
11.30mV
6.20mV
Pass
30% Load
11.20mV
9.90mV
12.10mV
7.50mV
Pass
40% Load
10.90mV
9.50mV
11.20mV
7.90mV
Pass
50% Load
9.90mV
10.30mV
11.80mV
9.10mV
Pass
60% Load
10.00mV
11.30mV
12.20mV
10.00mV
Pass
70% Load
11.00mV
11.20mV
12.50mV
10.10mV
Pass
80% Load
10.70mV
11.40mV
12.30mV
12.30mV
Pass
90% Load
10.00mV
11.80mV
12.10mV
13.30mV
Pass
100% Load
14.90mV
12.60mV
13.80mV
14.40mV
Pass
110% Load
15.30mV
13.00mV
13.30mV
15.20mV
Pass
Crossload1
17.90mV
10.40mV
13.20mV
6.20mV
Pass
Crossload2
16.10mV
12.50mV
13.20mV
10.80mV
Pass
The results above are not used in the certification process
Cooler Master V650 Gold SFX (2021)
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted