ErP Lot 3/6 2010: ✓
ErP Lot 3/6 2013: Partially
ErP Lot 3/6 2014, CEC: Failed
(EU) No 617/2013 Compliance
✓
Performance Summary
Efficiency Rating
SILVER
Noise Rating
Standard+
Average Efficiency (>1450 load combinations)
89.726%
Average Noise Output (>1450 Load Combinations)
37.77dBA
Average PF (>1450 Load Combinations)
0.979
Efficiency With 10W (≤500W) or 2% (>500W) Load
61.427%
Standby Power Consumption
0.1304W
12V Ripple (Full Load)
7.96mV
5V Ripple (Full Load)
5.92mV
3.3V Ripple (Full Load)
5.94mV
5VSB Ripple (Full Load)
5.54mV
12V Load Regulation
0.36%
5V Load Regulation
0.40%
3.3V Load Regulation
0.48%
5VSB Load Regulation
2.45%
Inrush Current
40.741A
Efficiency Rating
Noise Rating
Standard+
Average Efficiency (>1450 load combinations)
91.553%
Average Noise Output (>1450 Load Combinations)
36.26dBA
Average PF (>1450 Load Combinations)
0.933
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.2785W
12V Ripple (Full Load)
7.50mV
5V Ripple (Full Load)
6.13mV
3.3V Ripple (Full Load)
6.09mV
5VSB Ripple (Full Load)
5.48mV
12V Load Regulation
0.35%
5V Load Regulation
0.40%
3.3V Load Regulation
0.51%
5VSB Load Regulation
2.41%
Inrush Current
84.833A
12V Transient Response (150%)
0.00V
5V Transient Response (150%)
V
3.3V Transient Response (150%)
V
5VSB Transient Response (150%)
V
Hold-Up Time & Power Ok Signal
23.90ms
AC Loss to PWR_OK Hold Up Time
19.90ms
PWR_OK Inactive to DC Loss Delay
4.00ms
PSU Timings: T1 (20% / 100%)
0.0ms
0.0ms
PSU Timings: T3 (20% / 100%)
0.0ms
0.0ms
OPP (0.00°C / 0.00°C)
0.00%
0.00%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
23.9
AC Loss to PWR_OK Hold Up Time (ms)
19.9
PWR_OK Inactive to DC Loss Delay (ms)
4
Vampire Power
Tables
Graphs
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.229
53.882%
0.038
5.074V
0.425
115.39V
2
0.090A
0.457
63.209%
0.063
5.073V
0.723
115.39V
3
0.550A
2.784
74.359%
0.258
5.060V
3.744
115.39V
4
1.000A
5.048
75.052%
0.355
5.047V
6.726
115.38V
5
1.500A
7.551
74.963%
0.411
5.034V
10.073
115.38V
6
3.000A
14.966
72.710%
0.483
4.989V
20.583
115.37V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.229
39.965%
0.024
5.076V
0.573
230.28V
2
0.090A
0.457
51.464%
0.036
5.075V
0.888
230.28V
3
0.550A
2.784
69.496%
0.147
5.061V
4.006
230.28V
4
1.000A
5.049
72.836%
0.222
5.048V
6.932
230.28V
5
1.500A
7.552
74.083%
0.280
5.034V
10.194
230.28V
6
3.000A
14.965
74.246%
0.368
4.988V
20.156
230.28V
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
6.490A
1.992A
1.991A
0.992A
100.107
84.890%
1698
41.0
38.21°C
0.790
12.095V
5.022V
3.317V
5.042V
117.925
40.16°C
115.24V
2
13.970A
2.989A
2.983A
1.193A
199.804
89.563%
1706
41.2
38.43°C
0.994
12.089V
5.024V
3.319V
5.032V
223.088
40.54°C
115.11V
3
21.791A
3.483A
3.465A
1.394A
299.305
90.799%
1720
41.6
38.75°C
0.991
12.083V
5.025V
3.319V
5.022V
329.635
41.14°C
115.08V
4
29.683A
3.981A
3.977A
1.596A
399.725
91.226%
1770
41.8
39.13°C
0.993
12.078V
5.026V
3.320V
5.013V
438.170
41.87°C
115.24V
5
37.202A
4.973A
4.969A
1.800A
499.809
91.145%
1842
42.6
40.13°C
0.994
12.077V
5.029V
3.322V
5.002V
548.367
43.19°C
115.24V
6
44.700A
5.965A
5.957A
2.004A
599.975
90.881%
1842
42.6
40.90°C
0.994
12.084V
5.031V
3.325V
4.992V
660.180
44.43°C
115.24V
7
52.137A
6.956A
6.943A
2.208A
699.713
90.471%
1880
44.5
41.77°C
0.995
12.095V
5.034V
3.327V
4.982V
773.411
45.72°C
115.24V
8
59.635A
7.944A
7.929A
2.414A
800.240
90.048%
1940
45.8
42.88°C
0.995
12.104V
5.037V
3.330V
4.971V
888.686
47.59°C
115.24V
9
67.458A
8.440A
8.411A
2.417A
899.577
89.575%
2000
45.9
44.20°C
0.995
12.112V
5.037V
3.330V
4.967V
1004.276
49.46°C
115.24V
10
75.100A
8.934A
8.919A
3.035A
1000.001
88.868%
2080
46.2
45.63°C
0.996
12.121V
5.038V
3.330V
4.944V
1125.271
51.49°C
115.24V
11
83.293A
8.937A
8.927A
3.038A
1099.998
88.238%
2143
48.8
46.76°C
0.996
12.129V
5.037V
3.329V
4.939V
1246.620
53.49°C
115.24V
CL1
0.167A
14.002A
14.001A
0.000A
120.207
82.273%
2050
45.7
44.36°C
0.895
12.093V
5.069V
3.372V
5.060V
146.108
49.73°C
115.19V
CL2
83.353A
1.002A
1.002A
1.000A
1023.727
89.307%
2050
45.7
45.26°C
0.996
12.122V
5.007V
3.294V
5.005V
1146.305
50.89°C
115.24V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
8.131A
1.992A
1.988A
0.992A
119.897
88.967%
1129
29.9
39.89°C
0.625
12.091V
5.017V
3.316V
5.039V
134.766
42.16°C
230.21V
2
17.278A
2.989A
2.982A
1.194A
239.645
92.319%
1130
29.9
40.46°C
0.970
12.082V
5.017V
3.318V
5.027V
259.585
43.16°C
230.23V
3
26.775A
3.488A
3.461A
1.397A
359.216
92.552%
1748
41.6
41.23°C
0.982
12.072V
5.016V
3.319V
5.014V
388.123
44.21°C
230.24V
4
36.343A
3.989A
3.973A
1.600A
479.629
92.942%
1771
41.8
41.91°C
0.987
12.064V
5.013V
3.319V
5.002V
516.051
45.28°C
230.25V
5
45.519A
4.986A
4.965A
1.805A
599.810
92.846%
1805
42.6
42.41°C
0.988
12.068V
5.013V
3.321V
4.988V
646.027
46.22°C
230.26V
6
54.664A
5.984A
5.956A
2.011A
719.922
92.543%
1829
42.8
42.95°C
0.990
12.076V
5.013V
3.324V
4.975V
777.929
47.11°C
230.27V
7
63.768A
6.982A
6.944A
2.218A
839.672
92.222%
1863
43.7
43.21°C
0.990
12.084V
5.013V
3.326V
4.961V
910.489
48.22°C
230.29V
8
72.925A
7.980A
7.930A
2.426A
960.208
91.771%
1915
45.7
43.82°C
0.990
12.092V
5.013V
3.328V
4.948V
1046.314
49.81°C
230.26V
9
82.413A
8.482A
8.413A
2.429A
1079.533
91.273%
1966
45.9
44.43°C
0.990
12.098V
5.011V
3.328V
4.940V
1182.752
50.82°C
230.27V
10
91.736A
8.985A
8.924A
3.053A
1199.996
90.658%
2046
45.6
45.95°C
0.990
12.103V
5.009V
3.329V
4.914V
1323.652
52.77°C
230.27V
11
101.623A
8.992A
8.925A
3.059A
1320.055
90.003%
2047
45.6
46.63°C
0.990
12.107V
5.005V
3.327V
4.906V
1466.677
53.73°C
230.28V
CL1
0.155A
14.002A
14.001A
0.000A
119.795
82.465%
1854
43.2
42.26°C
0.630
12.089V
5.056V
3.366V
5.051V
145.267
46.32°C
230.31V
CL2
100.019A
1.003A
0.998A
1.000A
1223.899
91.026%
1963
45.9
45.80°C
0.990
12.104V
4.983V
3.296V
4.981V
1344.559
52.54°C
230.29V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.194A
0.499A
0.483A
0.197A
19.545
55.373%
0
<6.0
0.310
12.097V
5.016V
3.312V
5.068V
35.297
115.36V
2
2.454A
0.997A
0.995A
0.395A
39.980
79.474%
0
<6.0
0.537
12.095V
5.018V
3.314V
5.060V
50.306
115.33V
3
3.644A
1.494A
1.477A
0.594A
59.476
80.751%
1698
41.0
0.664
12.096V
5.020V
3.315V
5.054V
73.654
115.30V
4
4.900A
1.992A
1.989A
0.793A
79.874
83.142%
1680
40.5
0.736
12.096V
5.022V
3.317V
5.048V
96.069
115.27V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.181A
0.497A
0.480A
0.197A
19.373
68.713%
1122
29.7
0.466
12.101V
5.016V
3.312V
5.068V
28.194
230.19V
2
2.435A
0.995A
0.994A
0.395A
39.747
74.060%
1125
29.8
0.530
12.099V
5.017V
3.314V
5.061V
53.669
230.30V
3
3.626A
1.493A
1.474A
0.594A
59.244
83.352%
1126
29.8
0.529
12.097V
5.018V
3.315V
5.054V
71.077
230.40V
4
4.886A
1.992A
1.986A
0.793A
79.683
82.721%
1127
29.8
0.573
12.095V
5.019V
3.317V
5.047V
96.327
230.36V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
3.9 mV
3.5 mV
2.5 mV
2.9 mV
Pass
20% Load
3.9 mV
4.0 mV
2.8 mV
3.1 mV
Pass
30% Load
4.6 mV
3.9 mV
3.2 mV
3.3 mV
Pass
40% Load
5.3 mV
5.2 mV
3.9 mV
3.6 mV
Pass
50% Load
5.6 mV
4.9 mV
3.8 mV
4.0 mV
Pass
60% Load
5.9 mV
4.8 mV
4.2 mV
4.2 mV
Pass
70% Load
6.3 mV
4.9 mV
4.5 mV
4.4 mV
Pass
80% Load
7.1 mV
5.6 mV
5.5 mV
4.6 mV
Pass
90% Load
7.5 mV
5.5 mV
5.8 mV
4.6 mV
Pass
100% Load
8.0 mV
5.9 mV
5.9 mV
5.5 mV
Pass
110% Load
8.3 mV
6.2 mV
6.9 mV
5.9 mV
Pass
Crossload 1
3.7 mV
5.8 mV
5.0 mV
19.6 mV
Pass
Crossload 2
7.7 mV
4.4 mV
4.2 mV
3.7 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
8.5 mV
6.2 mV
9.9 mV
7.1 mV
Pass
20% Load
4.5 mV
5.4 mV
9.6 mV
7.8 mV
Pass
30% Load
4.9 mV
5.1 mV
11.2 mV
7.6 mV
Pass
40% Load
5.4 mV
5.9 mV
9.9 mV
7.5 mV
Pass
50% Load
5.4 mV
4.0 mV
10.5 mV
8.3 mV
Pass
60% Load
5.6 mV
4.6 mV
11.2 mV
8.4 mV
Pass
70% Load
6.1 mV
4.8 mV
11.4 mV
8.9 mV
Pass
80% Load
6.6 mV
5.1 mV
12.7 mV
9.4 mV
Pass
90% Load
6.9 mV
4.7 mV
12.6 mV
10.2 mV
Pass
100% Load
9.4 mV
5.6 mV
17.5 mV
10.3 mV
Pass
110% Load
9.7 mV
6.0 mV
17.7 mV
10.4 mV
Pass
Crossload 1
9.5 mV
4.7 mV
16.4 mV
25.0 mV
Pass
Crossload 2
8.4 mV
5.6 mV
17.7 mV
8.7 mV
Pass
The results above are not used in the certification process
Super Flower Leadex Gold 1000W
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted