This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.224
70.000%
0.336
4.990V
0.320
115.16V
2
0.090A
0.449
75.845%
0.364
4.990V
0.592
115.16V
3
0.550A
2.741
82.785%
0.466
4.984V
3.311
115.16V
4
1.000A
4.978
82.581%
0.505
4.978V
6.028
115.16V
5
1.500A
7.458
82.464%
0.529
4.972V
9.044
115.16V
6
2.999A
14.858
81.050%
0.560
4.954V
18.332
115.16V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.224
62.921%
0.266
4.990V
0.356
230.26V
2
0.090A
0.449
71.044%
0.291
4.989V
0.632
230.25V
3
0.550A
2.741
82.362%
0.375
4.982V
3.328
230.27V
4
1.000A
4.978
83.077%
0.408
4.977V
5.992
230.28V
5
1.500A
7.457
83.253%
0.430
4.970V
8.957
230.25V
6
3.001A
14.856
82.893%
0.469
4.951V
17.922
230.30V
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
4.327A
1.961A
1.992A
1.006A
74.949
86.517%
0
<6.0
45.63°C
0.945
12.329V
5.102V
3.311V
4.971V
86.629
40.20°C
115.15V
2
9.687A
3.066A
2.992A
1.209A
150.003
90.803%
0
<6.0
46.87°C
0.961
12.292V
4.903V
3.308V
4.963V
165.196
40.86°C
115.15V
3
15.387A
3.620A
3.494A
1.412A
224.998
92.179%
0
<6.0
47.95°C
0.973
12.276V
4.850V
3.306V
4.956V
244.087
41.30°C
115.15V
4
21.103A
3.910A
3.995A
1.617A
300.000
92.299%
0
<6.0
48.87°C
0.980
12.263V
5.118V
3.304V
4.949V
325.030
41.82°C
115.14V
5
26.451A
4.897A
5.001A
1.821A
374.349
91.861%
770
27.8
42.56°C
0.979
12.243V
5.106V
3.301V
4.941V
407.519
50.13°C
115.14V
6
31.850A
5.899A
6.004A
2.000A
449.146
91.518%
818
29.6
43.03°C
0.980
12.228V
5.088V
3.298V
4.934V
490.773
51.29°C
115.14V
7
37.285A
6.880A
7.010A
2.233A
524.591
91.034%
899
31.2
43.82°C
0.983
12.216V
5.089V
3.296V
4.926V
576.257
52.48°C
115.14V
8
42.736A
7.867A
8.012A
2.440A
599.911
90.440%
977
34.0
44.37°C
0.986
12.203V
5.086V
3.294V
4.918V
663.323
53.36°C
115.14V
9
48.554A
8.360A
8.504A
2.442A
674.400
89.915%
1052
34.9
44.68°C
0.988
12.191V
5.082V
3.292V
4.913V
750.039
54.15°C
115.14V
10
54.199A
8.901A
9.026A
3.061A
749.565
89.258%
1077
36.0
45.21°C
0.990
12.175V
5.056V
3.289V
4.901V
839.769
55.42°C
115.13V
11
60.432A
8.877A
9.030A
3.062A
824.723
88.603%
1127
37.2
46.64°C
0.991
12.163V
5.069V
3.288V
4.899V
930.805
57.30°C
115.12V
CL1
0.121A
14.000A
13.997A
0.000A
119.331
83.995%
0
<6.0
50.21°C
0.959
12.306V
5.109V
3.309V
4.967V
142.070
42.84°C
115.15V
CL2
62.488A
1.001A
0.999A
1.000A
774.732
89.579%
1142
37.3
45.31°C
0.990
12.185V
5.090V
3.293V
4.931V
864.859
55.55°C
115.12V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
4.328A
1.947A
1.992A
1.006A
74.950
86.906%
0
<6.0
45.45°C
0.888
12.328V
5.136V
3.310V
4.971V
86.243
40.12°C
230.32V
2
9.690A
2.925A
2.993A
1.209A
150.007
92.102%
0
<6.0
46.03°C
0.922
12.291V
5.130V
3.308V
4.964V
162.871
40.28°C
230.32V
3
15.397A
3.416A
3.495A
1.412A
225.006
93.374%
0
<6.0
47.39°C
0.942
12.272V
5.123V
3.306V
4.957V
240.973
41.28°C
230.33V
4
21.107A
3.913A
3.994A
1.616A
300.009
93.736%
0
<6.0
48.35°C
0.954
12.262V
5.111V
3.304V
4.950V
320.056
41.59°C
230.32V
5
26.451A
4.896A
4.999A
1.821A
374.350
93.511%
783
27.9
42.12°C
0.961
12.243V
5.108V
3.301V
4.942V
400.329
49.61°C
230.33V
6
31.852A
5.882A
6.004A
2.000A
449.164
93.356%
812
29.3
43.18°C
0.967
12.228V
5.102V
3.298V
4.934V
481.130
51.20°C
230.33V
7
37.286A
6.871A
7.012A
2.232A
524.600
93.116%
889
31.1
43.30°C
0.969
12.216V
5.095V
3.296V
4.926V
563.384
51.76°C
230.33V
8
42.735A
7.863A
8.012A
2.439A
599.900
92.776%
970
33.8
43.95°C
0.972
12.203V
5.089V
3.294V
4.919V
646.613
52.96°C
230.33V
9
48.552A
8.360A
8.503A
2.442A
674.384
92.452%
1046
34.9
44.09°C
0.975
12.191V
5.083V
3.292V
4.914V
729.441
53.79°C
230.33V
10
54.188A
8.864A
9.027A
3.060A
749.582
92.035%
1145
37.3
46.18°C
0.976
12.178V
5.076V
3.289V
4.901V
814.452
56.25°C
230.33V
11
60.430A
8.874A
9.033A
3.063A
824.820
91.615%
1351
40.9
47.19°C
0.977
12.165V
5.070V
3.288V
4.896V
900.307
58.07°C
230.33V
CL1
0.240A
14.000A
13.998A
0.000A
119.203
84.824%
0
<6.0
49.07°C
0.917
12.307V
4.996V
3.308V
4.966V
140.529
42.47°C
230.34V
CL2
62.486A
1.000A
1.000A
1.000A
774.643
92.497%
1154
37.4
46.48°C
0.976
12.184V
5.091V
3.293V
4.931V
837.478
56.89°C
230.33V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.211A
0.486A
0.497A
0.200A
19.971
77.320%
0
<6.0
0.889
12.242V
5.147V
3.314V
4.986V
25.829
115.14V
2
2.407A
0.971A
0.996A
0.401A
39.964
80.845%
0
<6.0
0.919
12.328V
5.143V
3.312V
4.981V
49.433
115.14V
3
3.614A
1.459A
1.493A
0.603A
59.997
84.384%
0
<6.0
0.937
12.328V
5.140V
3.311V
4.977V
71.100
115.14V
4
4.816A
1.946A
1.992A
0.804A
79.949
87.051%
0
<6.0
0.949
12.325V
5.138V
3.311V
4.973V
91.842
115.14V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.211A
0.486A
0.497A
0.200A
19.976
76.598%
0
<6.0
0.788
12.247V
5.147V
3.314V
4.986V
26.079
230.31V
2
2.407A
0.972A
0.996A
0.401A
39.968
80.719%
0
<6.0
0.855
12.328V
5.142V
3.312V
4.982V
49.515
230.31V
3
3.614A
1.458A
1.494A
0.603A
59.999
85.382%
0
<6.0
0.877
12.329V
5.140V
3.311V
4.978V
70.271
230.32V
4
4.818A
1.947A
1.992A
0.804A
79.950
87.709%
0
<6.0
0.890
12.320V
5.136V
3.310V
4.973V
91.154
230.32V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
7.26mV
5.93mV
6.86mV
10.75mV
Pass
20% Load
10.04mV
5.83mV
6.35mV
5.33mV
Pass
30% Load
11.96mV
6.83mV
7.39mV
7.34mV
Pass
40% Load
8.15mV
6.14mV
6.45mV
6.81mV
Pass
50% Load
8.15mV
6.72mV
6.88mV
6.76mV
Pass
60% Load
7.82mV
7.07mV
7.11mV
7.37mV
Pass
70% Load
13.32mV
8.89mV
9.18mV
9.15mV
Pass
80% Load
9.08mV
7.91mV
9.38mV
8.35mV
Pass
90% Load
13.69mV
9.32mV
11.05mV
10.23mV
Pass
100% Load
13.86mV
10.39mV
12.01mV
12.81mV
Pass
110% Load
14.44mV
10.65mV
12.20mV
12.50mV
Pass
Crossload1
15.08mV
8.66mV
10.95mV
6.08mV
Pass
Crossload2
13.52mV
8.69mV
9.10mV
6.58mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
9.62mV
6.26mV
6.35mV
5.15mV
Pass
20% Load
14.74mV
7.44mV
7.54mV
6.20mV
Pass
30% Load
12.37mV
6.89mV
7.00mV
6.96mV
Pass
40% Load
7.67mV
6.59mV
6.51mV
7.07mV
Pass
50% Load
7.92mV
7.07mV
6.63mV
6.89mV
Pass
60% Load
8.20mV
7.30mV
7.99mV
7.52mV
Pass
70% Load
9.11mV
8.55mV
7.44mV
7.50mV
Pass
80% Load
9.56mV
8.47mV
9.63mV
8.53mV
Pass
90% Load
9.54mV
10.02mV
10.14mV
8.41mV
Pass
100% Load
14.34mV
10.48mV
12.02mV
12.60mV
Pass
110% Load
14.03mV
10.32mV
12.72mV
12.23mV
Pass
Crossload1
16.24mV
9.00mV
10.98mV
5.82mV
Pass
Crossload2
13.42mV
8.03mV
8.25mV
6.40mV
Pass
The results above are not used in the certification process