This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.231
68.750%
0.039
5.123V
0.336
115.13V
2
0.090A
0.461
74.959%
0.069
5.120V
0.615
115.12V
3
0.550A
2.801
81.165%
0.269
5.091V
3.451
115.12V
4
1.000A
5.062
81.435%
0.346
5.062V
6.216
115.12V
5
1.500A
7.542
81.010%
0.388
5.027V
9.310
115.12V
6
2.500A
12.399
78.272%
0.433
4.960V
15.841
115.12V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.231
64.167%
0.012
5.123V
0.360
230.29V
2
0.090A
0.461
72.144%
0.022
5.120V
0.639
230.29V
3
0.550A
2.800
80.298%
0.111
5.090V
3.487
230.29V
4
1.000A
5.061
80.653%
0.179
5.060V
6.275
230.29V
5
1.500A
7.541
81.008%
0.232
5.027V
9.309
230.30V
6
2.500A
12.397
80.063%
0.300
4.958V
15.484
230.30V
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
5.263A
1.982A
1.987A
0.992A
84.975
88.085%
0
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
5.258A
1.981A
1.987A
0.992A
84.976
89.292%
0
<6.0
44.51°C
0.713
12.054V
5.046V
3.321V
5.041V
95.166
40.01°C
230.28V
2
11.546A
2.972A
2.986A
1.197A
170.067
92.705%
0
<6.0
46.37°C
0.877
12.054V
5.043V
3.316V
5.014V
183.450
41.02°C
230.28V
3
18.173A
3.472A
3.488A
1.403A
255.089
93.521%
484
<6.0
41.20°C
0.934
12.053V
5.040V
3.312V
4.988V
272.762
47.37°C
230.28V
4
24.802A
3.973A
3.992A
1.613A
340.110
93.779%
586
6.1
41.52°C
0.956
12.051V
5.037V
3.308V
4.962V
362.673
48.20°C
230.27V
5
31.074A
4.968A
4.996A
1.824A
425.135
93.213%
588
6.3
42.18°C
0.967
12.056V
5.034V
3.302V
4.935V
456.090
50.00°C
230.28V
6
37.298A
5.965A
6.007A
2.000A
509.487
92.928%
857
18.2
42.60°C
0.973
12.061V
5.031V
3.297V
4.911V
548.261
50.83°C
230.27V
7
43.617A
6.964A
7.020A
2.255A
594.963
92.491%
1239
30.7
43.40°C
0.978
12.056V
5.027V
3.291V
4.881V
643.269
52.48°C
230.27V
8
49.957A
7.967A
8.038A
2.476A
680.319
91.980%
1701
39.9
43.64°C
0.982
12.048V
5.023V
3.286V
4.849V
739.638
53.25°C
230.28V
9
56.656A
8.470A
8.536A
2.482A
765.239
91.593%
1798
41.1
44.31°C
0.985
12.050V
5.020V
3.281V
4.838V
835.480
54.27°C
230.28V
10
63.280A
8.972A
9.065A
2.597A
849.949
91.140%
1802
41.1
45.09°C
0.987
12.053V
5.018V
3.277V
4.816V
932.577
55.73°C
230.27V
11
70.297A
8.977A
9.072A
2.604A
934.727
90.611%
2162
46.0
47.06°C
0.989
12.056V
5.015V
3.274V
4.802V
1031.587
57.86°C
230.27V
CL1
0.101A
12.005A
12.000A
0.000A
101.170
85.700%
585
6.1
42.55°C
0.785
12.085V
5.034V
3.293V
5.087V
118.051
50.55°C
230.27V
CL2
70.018A
1.000A
1.001A
1.000A
857.553
91.787%
1801
41.4
45.22°C
0.987
12.058V
5.027V
3.299V
4.947V
934.284
55.68°C
230.27V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.235A
0.495A
0.496A
0.196A
19.999
75.439%
0
<6.0
0.645
12.022V
5.049V
3.328V
5.109V
26.510
115.14V
2
2.468A
0.991A
0.993A
0.393A
39.990
83.311%
0
<6.0
0.837
12.027V
5.048V
3.326V
5.091V
48.001
115.14V
3
3.704A
1.485A
1.491A
0.592A
60.021
86.071%
0
<6.0
0.920
12.032V
5.047V
3.324V
5.074V
69.734
115.14V
4
4.933A
1.982A
1.985A
0.791A
79.974
88.216%
0
<6.0
0.949
12.037V
5.046V
3.322V
5.056V
90.657
115.14V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.233A
0.493A
0.496A
0.196A
20.003
77.139%
0
<6.0
0.388
12.054V
5.049V
3.327V
5.107V
25.931
230.26V
2
2.463A
0.991A
0.993A
0.393A
39.993
84.652%
0
<6.0
0.554
12.053V
5.049V
3.325V
5.090V
47.244
230.28V
3
3.698A
1.486A
1.489A
0.592A
60.024
87.642%
0
<6.0
0.605
12.053V
5.048V
3.323V
5.073V
68.488
230.27V
4
4.926A
1.982A
1.987A
0.791A
79.975
89.154%
0
<6.0
0.701
12.053V
5.047V
3.321V
5.056V
89.704
230.28V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
13.50mV
11.60mV
17.80mV
4.20mV
Pass
20% Load
13.80mV
11.80mV
15.60mV
5.10mV
Pass
30% Load
14.40mV
12.60mV
16.90mV
5.70mV
Pass
40% Load
17.90mV
13.90mV
17.90mV
7.20mV
Pass
50% Load
16.80mV
16.50mV
18.90mV
8.90mV
Pass
60% Load
17.60mV
16.70mV
18.20mV
9.20mV
Pass
70% Load
18.10mV
17.30mV
18.80mV
9.90mV
Pass
80% Load
18.90mV
17.80mV
19.90mV
13.10mV
Pass
90% Load
19.00mV
19.40mV
20.70mV
15.40mV
Pass
100% Load
26.40mV
21.50mV
23.60mV
17.00mV
Pass
110% Load
27.40mV
22.90mV
24.30mV
19.40mV
Pass
Crossload1
21.00mV
15.50mV
20.00mV
10.10mV
Pass
Crossload2
26.20mV
20.00mV
21.70mV
12.80mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
12.60mV
11.40mV
13.90mV
4.20mV
Pass
20% Load
12.10mV
11.60mV
14.40mV
4.80mV
Pass
30% Load
12.40mV
12.10mV
14.90mV
5.50mV
Pass
40% Load
14.60mV
12.00mV
14.10mV
6.40mV
Pass
50% Load
14.70mV
15.10mV
16.00mV
8.10mV
Pass
60% Load
15.30mV
15.80mV
15.90mV
8.30mV
Pass
70% Load
15.90mV
14.60mV
15.90mV
8.40mV
Pass
80% Load
17.10mV
15.70mV
16.70mV
9.00mV
Pass
90% Load
17.60mV
17.00mV
17.10mV
9.80mV
Pass
100% Load
25.60mV
18.30mV
22.20mV
11.20mV
Pass
110% Load
26.40mV
19.10mV
20.40mV
11.90mV
Pass
Crossload1
17.50mV
14.70mV
19.90mV
9.80mV
Pass
Crossload2
24.80mV
16.60mV
19.20mV