This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.230
72.100%
0.035
5.111V
0.319
115.15V
2
0.090A
0.460
77.052%
0.065
5.111V
0.597
115.15V
3
0.550A
2.805
81.659%
0.260
5.101V
3.435
115.15V
4
1.000A
5.092
81.655%
0.333
5.093V
6.236
115.16V
5
1.500A
7.622
79.421%
0.376
5.082V
9.597
115.16V
6
2.499A
12.652
76.814%
0.417
5.062V
16.471
115.16V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.230
61.995%
0.013
5.112V
0.371
230.30V
2
0.090A
0.460
69.697%
0.023
5.111V
0.660
230.30V
3
0.550A
2.805
78.090%
0.115
5.102V
3.592
230.30V
4
1.000A
5.093
79.978%
0.180
5.093V
6.368
230.30V
5
1.500A
7.622
79.996%
0.232
5.082V
9.528
230.30V
6
2.499A
12.653
79.845%
0.294
5.063V
15.847
230.30V
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
2.739A
1.989A
1.997A
0.984A
54.953
83.204%
605
16.3
35.38°C
0.951
12.178V
5.029V
3.305V
5.082V
66.046
40.09°C
115.16V
2
6.503A
2.985A
2.998A
1.183A
110.008
86.646%
607
16.3
35.97°C
0.976
12.165V
5.026V
3.303V
5.070V
126.963
42.60°C
115.16V
3
10.612A
3.483A
3.499A
1.384A
164.997
87.747%
609
16.4
36.55°C
0.982
12.151V
5.025V
3.301V
5.057V
188.037
43.5°C
115.16V
4
14.730A
3.982A
4.001A
1.585A
219.996
87.870%
612
16.4
37.20°C
0.988
12.138V
5.023V
3.300V
5.047V
250.366
44.52°C
115.16V
5
18.515A
4.977A
5.002A
1.788A
274.981
87.276%
615
16.5
37.57°C
0.989
12.124V
5.024V
3.299V
5.034V
315.071
44.99°C
115.15V
6
22.312A
5.971A
6.002A
1.993A
329.972
86.392%
765
22.0
37.62°C
0.991
12.108V
5.026V
3.299V
5.018V
381.947
45.58°C
115.15V
7
26.124A
6.969A
7.007A
2.197A
385.044
85.410%
1061
30.8
38.09°C
0.992
12.094V
5.024V
3.297V
5.006V
450.821
46.7°C
115.15V
8
29.933A
7.970A
8.012A
2.402A
439.952
84.303%
1391
38.7
38.93°C
0.992
12.079V
5.021V
3.295V
4.994V
521.871
47.9°C
115.15V
9
34.144A
8.469A
8.503A
2.406A
494.431
83.324%
1678
44.0
39.74°C
0.993
12.065V
5.018V
3.292V
4.987V
593.382
48.90°C
115.15V
10
38.371A
8.970A
9.024A
2.512A
549.563
82.184%
1822
46.8
39.74°C
0.993
12.050V
5.017V
3.291V
4.976V
668.696
50.55°C
115.15V
11
43.005A
8.974A
9.030A
2.515A
604.784
81.331%
1822
46.8
40.29°C
0.994
12.036V
5.015V
3.289V
4.969V
743.605
51.43°C
115.14V
CL1
0.100A
13.000A
12.998A
0.000A
109.566
80.343%
619
16.6
35.81°C
0.976
12.155V
5.032V
3.304V
5.069V
136.372
43.01°C
115.17V
CL2
45.498A
1.000A
1.000A
1.000A
561.736
83.008%
1826
46.9
38.35°C
0.993
12.053V
5.022V
3.296V
5.019V
676.726
50.99°C
115.14V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
2.740A
1.989A
1.997A
0.984A
54.958
84.219%
606
16.3
35.12°C
0.829
12.174V
5.029V
3.305V
5.080V
65.256
39.82°C
230.34V
2
6.507A
2.985A
2.998A
1.184A
110.021
88.253%
608
16.4
35.64°C
0.918
12.161V
5.026V
3.303V
5.068V
124.665
40.56°C
230.34V
3
10.615A
3.484A
3.500A
1.385A
165.012
89.357%
612
16.4
35.73°C
0.948
12.148V
5.024V
3.301V
5.056V
184.667
41.54°C
230.34V
4
14.735A
3.983A
4.002A
1.586A
220.010
89.528%
612
16.4
36.26°C
0.963
12.135V
5.023V
3.300V
5.045V
245.745
42.70°C
230.34V
5
18.521A
4.978A
5.003A
1.789A
274.998
89.203%
615
16.5
37.61°C
0.967
12.121V
5.023V
3.299V
5.033V
308.284
44.36°C
230.34V
6
22.316A
5.972A
6.004A
1.993A
329.984
88.593%
717
20.1
37.94°C
0.974
12.107V
5.025V
3.299V
5.019V
372.471
45.50°C
230.34V
7
26.127A
6.969A
7.008A
2.197A
385.056
87.733%
1054
30.5
37.99°C
0.978
12.093V
5.024V
3.297V
5.005V
438.897
45.77°C
230.33V
8
29.934A
7.970A
8.013A
2.403A
439.952
86.776%
1429
39.5
38.99°C
0.982
12.078V
5.021V
3.294V
4.993V
506.997
47.7°C
230.33V
9
34.148A
8.469A
8.504A
2.406A
494.450
86.014%
1704
46.4
39.49°C
0.985
12.065V
5.019V
3.292V
4.986V
574.845
48.51°C
230.33V
10
38.371A
8.971A
9.025A
2.512A
549.562
85.159%
1826
46.9
40.02°C
0.987
12.050V
5.017V
3.290V
4.976V
645.338
49.38°C
230.33V
11
43.002A
8.973A
9.030A
2.515A
604.778
84.525%
1824
46.9
39.86°C
0.988
12.036V
5.015V
3.288V
4.969V
715.501
50.88°C
230.33V
CL1
0.100A
13.000A
12.998A
0.000A
109.557
81.770%
619
16.6
36.77°C
0.926
12.154V
5.032V
3.303V
5.069V
133.982
43.06°C
230.34V
CL2
45.499A
1.000A
1.000A
1.000A
561.739
86.016%
1827
47.0
38.50°C
0.987
12.053V
5.021V
3.295V
5.019V
653.062
47.30°C
230.33V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.217A
0.497A
0.499A
0.196A
19.983
72.631%
601
16.2
0.884
12.186V
5.032V
3.308V
5.104V
27.513
115.17V
2
2.436A
0.994A
0.998A
0.392A
39.971
80.959%
602
16.2
0.937
12.181V
5.030V
3.307V
5.097V
49.372
115.16V
3
3.659A
1.492A
1.498A
0.589A
60.003
84.576%
603
16.3
0.953
12.177V
5.029V
3.305V
5.090V
70.946
115.16V
4
4.877A
1.989A
1.997A
0.787A
79.954
85.785%
604
16.3
0.967
12.172V
5.028V
3.304V
5.082V
93.203
115.16V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.218A
0.497A
0.499A
0.196A
19.988
73.286%
602
16.2
0.601
12.183V
5.031V
3.307V
5.102V
27.274
230.35V
2
2.437A
0.994A
0.998A
0.393A
39.977
82.085%
604
16.3
0.765
12.178V
5.029V
3.306V
5.095V
48.702
230.35V
3
3.660A
1.492A
1.498A
0.590A
60.008
85.471%
605
16.3
0.842
12.172V
5.028V
3.305V
5.088V
70.209
230.35V
4
4.878A
1.990A
1.998A
0.787A
79.958
87.215%
606
16.3
0.883
12.168V
5.028V
3.304V
5.080V
91.679
230.35V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
5.87mV
10.27mV
9.45mV
7.74mV
Pass
20% Load
6.58mV
12.30mV
10.16mV
9.26mV
Pass
30% Load
7.29mV
11.89mV
10.21mV
7.95mV
Pass
40% Load
9.01mV
13.77mV
10.62mV
11.33mV
Pass
50% Load
9.72mV
14.79mV
12.59mV
9.11mV
Pass
60% Load
11.90mV
13.67mV
12.18mV
9.56mV
Pass
70% Load
12.25mV
13.92mV
13.04mV
13.00mV
Pass
80% Load
14.73mV
16.62mV
15.67mV
16.04mV
Pass
90% Load
16.76mV
17.23mV
17.24mV
15.43mV
Pass
100% Load
27.38mV
19.55mV
18.73mV
16.13mV
Pass
110% Load
34.65mV
21.42mV
20.87mV
17.17mV
Pass
Crossload1
8.97mV
14.94mV
16.37mV
7.77mV
Pass
Crossload2
31.40mV
16.41mV
16.48mV
11.41mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
6.13mV
9.15mV
9.81mV
7.79mV
Pass
20% Load
6.68mV
10.32mV
9.96mV
9.72mV
Pass
30% Load
7.04mV
10.32mV
10.36mV
8.10mV
Pass
40% Load
8.05mV
11.64mV
11.17mV
12.20mV
Pass
50% Load
9.01mV
12.35mV
11.83mV
9.06mV
Pass
60% Load
9.97mV
12.70mV
12.79mV
8.66mV
Pass
70% Load
10.89mV
13.87mV
13.65mV
14.07mV
Pass
80% Load
13.11mV
14.23mV
15.52mV
16.55mV
Pass
90% Load
15.34mV
16.97mV
17.39mV
15.58mV
Pass
100% Load
25.27mV
18.55mV
18.10mV
14.42mV
Pass
110% Load
33.68mV
20.59mV
20.66mV
16.48mV
Pass
Crossload1
9.01mV
14.83mV
18.29mV
7.97mV
Pass
Crossload2
30.08mV
15.99mV
16.16mV
11.29mV
Pass
The results above are not used in the certification process
Thermaltake Smart BM2 550W
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted