This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
115V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
115V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC) 115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.214
68.153%
0.051
5.132V
0.314
115.19V
2
0.087A
0.447
73.520%
0.096
5.130V
0.608
115.19V
3
0.542A
2.774
77.313%
0.333
5.119V
3.588
115.18V
4
1.002A
5.118
77.346%
0.405
5.108V
6.617
115.19V
5
1.502A
7.652
77.153%
0.441
5.096V
9.918
115.19V
6
3.001A
15.158
75.980%
0.485
5.051V
19.950
115.19V
Supplementary Tests (For Reference)
Typical Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
2.734A
1.996A
1.980A
0.981A
54.779
83.958%
0
<6.0
47.11°C
0.946
12.141V
5.008V
3.328V
5.097V
65.246
38.61°C
115.20V
2
6.497A
2.992A
2.975A
1.179A
109.735
88.540%
0
<6.0
48.21°C
0.979
12.141V
5.005V
3.323V
5.084V
123.939
39.00°C
115.20V
3
10.607A
3.504A
3.489A
1.379A
164.892
89.718%
0
<6.0
49.90°C
0.986
12.142V
5.001V
3.321V
5.070V
183.790
39.35°C
115.20V
4
14.709A
4.008A
3.973A
1.580A
219.801
89.850%
645
11.9
39.49°C
0.989
12.142V
4.998V
3.318V
5.057V
244.633
59.63°C
115.19V
5
18.465A
5.009A
4.977A
1.783A
274.694
89.539%
550
10.4
40.75°C
0.990
12.143V
4.990V
3.313V
5.042V
306.786
61.01°C
115.19V
6
22.230A
6.016A
5.980A
1.986A
329.684
89.021%
560
10.5
41.00°C
0.990
12.142V
4.986V
3.309V
5.027V
370.342
63.75°C
115.19V
7
25.990A
7.024A
6.985A
2.194A
384.637
88.467%
880
20.6
41.63°C
0.990
12.142V
4.981V
3.305V
5.011V
434.780
61.30°C
115.21V
8
29.753A
8.046A
7.999A
2.400A
439.575
87.623%
1325
31.4
42.45°C
0.991
12.139V
4.975V
3.299V
4.994V
501.668
58.38°C
115.23V
9
33.952A
8.552A
8.523A
2.405A
494.626
86.792%
1850
40.2
43.72°C
0.992
12.136V
4.970V
3.296V
4.985V
569.899
56.43°C
115.18V
10
37.892A
9.067A
9.020A
3.020A
549.503
85.891%
2310
45.1
44.95°C
0.992
12.134V
4.967V
3.293V
4.961V
639.765
57.10°C
115.17V
11
42.424A
9.070A
9.024A
3.026A
604.425
85.029%
2320
45.2
46.28°C
0.992
12.133V
4.964V
3.290V
4.951V
710.849
60.03°C
115.16V
CL1
0.099A
12.014A
12.004A
0.004A
100.991
85.016%
621
11.6
44.12°C
0.976
12.149V
4.991V
3.316V
5.091V
118.791
54.60°C
115.20V
CL2
44.972A
1.005A
1.004A
1.002A
558.916
86.521%
2310
45.1
45.36°C
0.992
12.131V
4.979V
3.304V
5.030V
645.992
57.63°C
115.18V
The results above are not used in the certification process
Light Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.202A
0.490A
0.479A
0.196A
19.643
71.080%
0
<6.0
0.783
12.134V
5.014V
3.333V
5.124V
27.635
115.20V
2
2.428A
0.991A
0.990A
0.391A
39.724
81.250%
0
<6.0
0.911
12.136V
5.008V
3.328V
5.116V
48.891
115.20V
3
3.658A
1.489A
1.499A
0.585A
59.832
85.206%
0
<6.0
0.952
12.137V
5.008V
3.328V
5.108V
70.220
115.20V
4
4.874A
1.996A
1.983A
0.781A
79.738
87.243%
0
<6.0
0.968
12.139V
5.007V
3.326V
5.099V
91.398
115.20V
The results above are not used in the certification process
Ripple Measurements 115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
10.1 mV
5.6 mV
8.2 mV
6.3 mV
Pass
20% Load
12.7 mV
5.7 mV
8.7 mV
6.0 mV
Pass
30% Load
15.1 mV
6.1 mV
8.2 mV
5.7 mV
Pass
40% Load
16.4 mV
6.9 mV
8.3 mV
6.2 mV
Pass
50% Load
18.1 mV
6.6 mV
8.8 mV
6.6 mV
Pass
60% Load
19.6 mV
7.5 mV
9.7 mV
6.9 mV
Pass
70% Load
21.2 mV
8.2 mV
10.1 mV
8.0 mV
Pass
80% Load
22.8 mV
8.7 mV
9.9 mV
8.0 mV
Pass
90% Load
24.6 mV
10.4 mV
10.7 mV
7.9 mV
Pass
100% Load
26.4 mV
12.8 mV
12.7 mV
10.3 mV
Pass
110% Load
28.1 mV
13.1 mV
13.4 mV
10.2 mV
Pass
Crossload 1
15.6 mV
9.4 mV
8.6 mV
7.9 mV
Pass
Crossload 2
25.5 mV
10.8 mV
11.4 mV
9.5 mV
Pass
The results above are not used in the certification process
Seasonic Focus Plus Gold 550W (#2)
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted