This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
115V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
115V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC) 115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.041A
0.212
68.167%
0.050
5.128V
0.311
115.21V
2
0.087A
0.445
73.920%
0.095
5.126V
0.602
115.21V
3
0.542A
2.771
77.968%
0.329
5.116V
3.554
115.38V
4
1.002A
5.113
78.085%
0.400
5.105V
6.548
115.34V
5
1.501A
7.647
78.246%
0.436
5.094V
9.773
115.34V
6
3.001A
15.153
76.176%
0.485
5.049V
19.892
115.33V
Supplementary Tests (For Reference)
Typical Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
4.380A
1.996A
1.994A
0.981A
74.721
85.411%
0
|6
42.05°C
0.955
12.131V
5.012V
3.303V
5.095V
87.484
38.38°C
115.20V
2
9.797A
2.992A
2.999A
1.180A
149.732
89.414%
0
|6
42.62°C
0.983
12.132V
5.008V
3.299V
5.083V
167.459
38.80°C
115.20V
3
15.560A
3.498A
3.517A
1.379A
224.860
90.296%
700
14.6
38.85°C
0.989
12.132V
5.004V
3.295V
5.071V
249.026
52.18°C
115.19V
4
21.307A
4.004A
4.008A
1.580A
299.705
90.300%
550
10.4
39.00°C
0.991
12.132V
5.000V
3.292V
5.059V
331.900
53.36°C
115.19V
5
26.716A
5.002A
5.014A
1.780A
374.628
89.703%
560
10.5
40.37°C
0.990
12.134V
4.996V
3.288V
5.045V
417.633
55.25°C
115.27V
6
32.118A
6.016A
6.026A
1.985A
449.554
89.092%
735
15.4
40.60°C
0.991
12.135V
4.990V
3.284V
5.034V
504.597
55.86°C
115.17V
7
37.534A
7.018A
7.042A
2.190A
524.474
88.327%
1325
31.4
42.34°C
0.991
12.133V
4.986V
3.279V
5.019V
593.787
57.82°C
115.17V
8
42.959A
8.034A
8.062A
2.395A
599.416
87.492%
1960
41.4
43.07°C
0.992
12.128V
4.981V
3.275V
5.006V
685.112
59.02°C
115.16V
9
48.809A
8.539A
8.586A
2.400A
674.436
86.791%
2310
45.1
44.06°C
0.992
12.126V
4.977V
3.271V
4.998V
777.079
60.62°C
115.16V
10
54.388A
9.058A
9.085A
3.011A
749.284
85.960%
2320
45.2
45.87°C
0.993
12.127V
4.973V
3.268V
4.977V
871.661
62.87°C
115.15V
11
60.564A
9.067A
9.093A
3.015A
824.135
84.992%
2320
45.2
47.30°C
0.993
12.126V
4.970V
3.265V
4.970V
969.658
65.69°C
115.15V
CL1
0.099A
12.013A
12.004A
0.004A
100.757
84.378%
560
10.5
43.09°C
0.973
12.145V
4.998V
3.290V
5.101V
119.412
55.37°C
115.21V
CL2
61.936A
1.005A
1.002A
1.001A
764.309
86.243%
2320
45.2
46.36°C
0.993
12.125V
4.982V
3.279V
5.037V
886.231
62.78°C
115.16V
The results above are not used in the certification process
Light Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.205A
0.493A
0.482A
0.195A
19.665
68.239%
0
<6.0
0.750
12.115V
5.017V
3.308V
5.121V
28.818
115.20V
2
2.433A
0.991A
0.997A
0.391A
39.753
79.148%
0
<6.0
0.884
12.120V
5.015V
3.305V
5.114V
50.226
115.20V
3
3.665A
1.487A
1.509A
0.585A
59.862
83.966%
0
<6.0
0.938
12.124V
5.013V
3.304V
5.106V
71.293
115.20V
4
4.880A
1.996A
1.995A
0.780A
79.756
86.353%
0
<6.0
0.959
12.128V
5.012V
3.303V
5.099V
92.360
115.21V
The results above are not used in the certification process
Ripple Measurements 115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
8.9 mV
6.0 mV
8.2 mV
5.7 mV
Pass
20% Load
12.7 mV
6.1 mV
8.5 mV
5.9 mV
Pass
30% Load
15.2 mV
6.3 mV
8.5 mV
6.1 mV
Pass
40% Load
17.1 mV
7.8 mV
10.4 mV
6.5 mV
Pass
50% Load
18.3 mV
7.8 mV
9.1 mV
6.5 mV
Pass
60% Load
20.2 mV
10.4 mV
10.6 mV
7.2 mV
Pass
70% Load
21.9 mV
11.4 mV
11.6 mV
8.4 mV
Pass
80% Load
23.0 mV
11.6 mV
11.8 mV
9.4 mV
Pass
90% Load
26.2 mV
13.1 mV
13.1 mV
9.8 mV
Pass
100% Load
27.9 mV
13.2 mV
14.6 mV
11.6 mV
Pass
110% Load
28.6 mV
15.4 mV
15.9 mV
12.2 mV
Pass
Crossload 1
12.3 mV
11.3 mV
9.4 mV
8.2 mV
Pass
Crossload 2
27.2 mV
10.6 mV
12.8 mV
9.2 mV
Pass
The results above are not used in the certification process
Seasonic Focus Plus Gold 750W (#2)
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted