This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.225
66.568%
0.036
5.001V
0.338
115.13V
2
0.090A
0.450
72.698%
0.065
4.999V
0.619
115.13V
3
0.550A
2.740
80.328%
0.271
4.980V
3.411
115.13V
4
1.000A
4.962
80.304%
0.367
4.961V
6.179
115.12V
5
1.500A
7.410
79.901%
0.422
4.939V
9.274
115.13V
6
3.000A
14.647
78.968%
0.494
4.882V
18.548
115.13V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.225
59.682%
0.012
5.001V
0.377
230.27V
2
0.090A
0.450
67.976%
0.021
4.998V
0.662
230.27V
3
0.550A
2.739
77.945%
0.105
4.978V
3.514
230.27V
4
1.000A
4.961
79.592%
0.172
4.960V
6.233
230.27V
5
1.500A
7.407
79.313%
0.232
4.937V
9.339
230.27V
6
3.000A
14.615
78.876%
0.339
4.871V
18.529
230.27V
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
6.397A
1.990A
1.977A
0.999A
100.008
89.985%
0
<6.0
43.96°C
0.976
12.257V
5.025V
3.338V
5.006V
111.139
40.01°C
115.12V
2
13.802A
2.986A
2.970A
1.200A
200.045
92.369%
0
<6.0
44.71°C
0.985
12.255V
5.022V
3.335V
5.001V
216.571
40.40°C
115.12V
3
21.545A
3.487A
3.465A
1.402A
300.023
92.841%
0
<6.0
46.08°C
0.986
12.252V
5.019V
3.333V
4.995V
323.157
41.18°C
115.12V
4
29.268A
3.988A
3.963A
1.604A
399.742
92.705%
0
<6.0
46.83°C
0.991
12.250V
5.017V
3.331V
4.988V
431.200
41.53°C
115.11V
5
36.694A
4.988A
4.957A
1.806A
499.868
92.251%
608
24.6
42.20°C
0.994
12.246V
5.014V
3.329V
4.984V
541.857
48.45°C
115.12V
6
44.125A
5.989A
5.953A
2.000A
599.990
91.662%
701
27.1
42.73°C
0.995
12.243V
5.011V
3.326V
4.978V
654.565
49.84°C
115.11V
7
51.528A
6.991A
6.954A
2.213A
699.775
90.902%
1202
41.4
43.66°C
0.996
12.239V
5.008V
3.323V
4.973V
769.814
51.89°C
115.11V
8
59.000A
7.997A
7.953A
2.417A
800.302
90.070%
1748
50.6
43.86°C
0.997
12.235V
5.005V
3.320V
4.968V
888.538
52.53°C
115.11V
9
66.796A
8.500A
8.441A
2.417A
899.578
89.178%
2016
52.6
44.33°C
0.997
12.232V
5.003V
3.317V
4.967V
1008.749
53.48°C
115.10V
10
74.437A
9.003A
8.961A
3.031A
1000.014
88.350%
2010
52.6
45.31°C
0.998
12.229V
5.000V
3.315V
4.950V
1131.883
55.71°C
115.10V
11
82.628A
9.007A
8.966A
3.033A
1100.027
87.454%
2006
52.6
47.14°C
0.998
12.227V
4.999V
3.313V
4.947V
1257.837
57.87°C
115.10V
CL1
0.102A
15.005A
15.000A
0.000A
126.330
86.572%
859
31.2
41.87°C
0.988
12.258V
5.007V
3.330V
5.060V
145.924
48.14°C
115.14V
CL2
83.020A
0.999A
1.000A
1.000A
1028.400
88.415%
2008
52.6
45.76°C
0.998
12.227V
5.013V
3.321V
4.985V
1163.155
55.64°C
115.11V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
6.398A
1.990A
1.976A
0.999A
100.005
91.508%
0
<6.0
44.45°C
0.834
12.255V
5.025V
3.338V
5.006V
109.286
40.15°C
230.24V
2
13.804A
2.987A
2.968A
1.200A
200.038
93.818%
0
<6.0
45.83°C
0.926
12.253V
5.021V
3.335V
5.001V
213.219
40.76°C
230.25V
3
21.546A
3.488A
3.465A
1.402A
300.018
94.365%
0
<6.0
46.89°C
0.956
12.251V
5.019V
3.333V
4.995V
317.932
41.11°C
230.24V
4
29.268A
3.988A
3.963A
1.604A
399.715
94.403%
0
<6.0
48.34°C
0.970
12.249V
5.017V
3.331V
4.989V
423.415
41.60°C
230.25V
5
36.692A
4.988A
4.960A
1.806A
499.848
94.127%
610
25.1
42.38°C
0.978
12.246V
5.014V
3.328V
4.984V
531.033
49.56°C
230.25V
6
44.122A
5.988A
5.955A
2.000A
599.963
93.802%
622
23.3
42.79°C
0.983
12.243V
5.012V
3.326V
4.980V
639.609
50.61°C
230.25V
7
51.521A
6.991A
6.954A
2.212A
699.738
93.346%
1072
38.6
43.61°C
0.987
12.240V
5.008V
3.323V
4.974V
749.615
52.06°C
230.26V
8
58.996A
7.996A
7.954A
2.416A
800.307
92.696%
1703
51.0
44.15°C
0.988
12.236V
5.005V
3.320V
4.969V
863.366
53.26°C
230.26V
9
66.791A
8.498A
8.439A
2.417A
899.578
92.068%
2017
52.7
44.71°C
0.988
12.233V
5.003V
3.318V
4.968V
977.078
54.31°C
230.26V
10
74.427A
9.002A
8.963A
3.031A
999.980
91.595%
2011
52.6
45.75°C
0.989
12.230V
5.001V
3.315V
4.951V
1091.744
56.18°C
230.26V
11
82.629A
9.006A
8.966A
3.032A
1100.035
91.013%
2002
52.6
46.61°C
0.990
12.227V
4.999V
3.313V
4.949V
1208.651
57.47°C
230.26V
CL1
0.102A
15.005A
15.001A
0.000A
126.319
88.027%
695
26.5
42.90°C
0.878
12.259V
5.006V
3.330V
5.062V
143.501
49.55°C
230.27V
CL2
83.015A
1.001A
1.000A
1.000A
1028.430
91.730%
2002
52.6
45.51°C
0.989
12.228V
5.013V
3.321V
4.985V
1121.148
56.26°C
230.27V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.211A
0.497A
0.493A
0.199A
19.990
73.753%
0
<6.0
0.821
12.255V
5.031V
3.342V
5.027V
27.104
115.11V
2
2.422A
0.995A
0.986A
0.399A
39.981
83.162%
0
<6.0
0.915
12.256V
5.027V
3.339V
5.020V
48.076
115.11V
3
3.636A
1.491A
1.483A
0.598A
60.012
87.037%
0
<6.0
0.949
12.257V
5.026V
3.339V
5.016V
68.950
115.12V
4
4.844A
1.990A
1.975A
0.798A
79.964
89.009%
0
<6.0
0.970
12.257V
5.025V
3.338V
5.011V
89.838
115.11V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.211A
0.497A
0.494A
0.199A
19.989
73.880%
0
<6.0
0.488
12.253V
5.031V
3.342V
5.027V
27.056
230.23V
2
2.422A
0.995A
0.987A
0.399A
39.979
84.257%
0
<6.0
0.647
12.254V
5.027V
3.339V
5.019V
47.449
230.23V
3
3.636A
1.492A
1.484A
0.598A
60.010
88.173%
0
<6.0
0.737
12.254V
5.026V
3.339V
5.016V
68.059
230.24V
4
4.844A
1.990A
1.977A
0.798A
79.962
90.155%
0
<6.0
0.792
12.255V
5.025V
3.338V
5.011V
88.694
230.24V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
6.30mV
6.10mV
24.50mV
3.70mV
Pass
20% Load
7.80mV
7.00mV
24.50mV
4.80mV
Pass
30% Load
8.70mV
6.70mV
25.20mV
4.70mV
Pass
40% Load
8.00mV
6.30mV
23.60mV
4.80mV
Pass
50% Load
8.50mV
6.60mV
24.60mV
5.00mV
Pass
60% Load
8.60mV
7.00mV
25.70mV
5.70mV
Pass
70% Load
9.70mV
6.80mV
26.00mV
6.00mV
Pass
80% Load
10.20mV
6.70mV
24.20mV
7.30mV
Pass
90% Load
10.90mV
7.20mV
25.60mV
7.10mV
Pass
100% Load
16.90mV
8.20mV
18.20mV
8.20mV
Pass
110% Load
16.70mV
8.80mV
16.40mV
9.20mV
Pass
Crossload1
10.10mV
7.60mV
16.50mV
4.40mV
Pass
Crossload2
16.30mV
7.50mV
16.50mV
7.90mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
6.30mV
6.10mV
22.50mV
3.80mV
Pass
20% Load
8.20mV
6.80mV
17.10mV
4.50mV
Pass
30% Load
10.40mV
7.20mV
24.10mV
4.50mV
Pass
40% Load
8.40mV
6.20mV
23.80mV
4.20mV
Pass
50% Load
7.60mV
6.70mV
23.40mV
4.60mV
Pass
60% Load
8.40mV
6.70mV
25.70mV
5.60mV
Pass
70% Load
9.40mV
6.60mV
24.20mV
6.00mV
Pass
80% Load
10.00mV
6.50mV
15.00mV
6.60mV
Pass
90% Load
10.50mV
6.90mV
16.40mV
6.70mV
Pass
100% Load
16.60mV
7.80mV
29.10mV
7.90mV
Pass
110% Load
17.70mV
7.70mV
28.50mV
8.30mV
Pass
Crossload1
10.90mV
8.10mV
26.50mV
4.80mV
Pass
Crossload2
16.10mV
6.80mV
15.80mV
7.50mV
Pass
The results above are not used in the certification process