This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.227
54.831%
0.060
5.043V
0.414
115.11V
2
0.090A
0.454
66.084%
0.096
5.042V
0.687
115.11V
3
0.550A
2.765
79.568%
0.316
5.026V
3.475
115.11V
4
1.000A
5.010
80.327%
0.395
5.010V
6.237
115.11V
5
1.500A
7.487
80.670%
0.435
4.991V
9.281
115.11V
6
3.000A
14.807
78.887%
0.482
4.935V
18.770
115.11V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.227
50.221%
0.020
5.044V
0.452
230.22V
2
0.090A
0.454
61.937%
0.032
5.042V
0.733
230.22V
3
0.550A
2.764
78.234%
0.140
5.026V
3.533
230.22V
4
1.000A
5.010
79.398%
0.217
5.009V
6.310
230.21V
5
1.500A
7.488
79.778%
0.276
4.991V
9.386
230.22V
6
3.000A
14.811
79.275%
0.366
4.937V
18.683
230.22V
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.582A
1.976A
1.971A
1.000A
64.964
86.907%
236
7.0
40.17°C
0.962
12.108V
5.057V
3.350V
4.998V
74.751
42.96°C
115.11V
2
8.195A
2.971A
2.963A
1.204A
130.029
90.725%
239
7.1
40.70°C
0.972
12.096V
5.049V
3.342V
4.983V
143.322
44.02°C
115.11V
3
13.158A
3.469A
3.464A
1.409A
195.040
91.911%
240
7.1
41.25°C
0.982
12.083V
5.044V
3.335V
4.969V
212.205
44.85°C
115.11V
4
18.132A
3.970A
3.966A
1.615A
260.049
92.228%
242
7.1
41.37°C
0.987
12.070V
5.037V
3.328V
4.954V
281.963
45.90°C
115.11V
5
22.772A
4.972A
4.969A
1.823A
325.095
92.075%
245
7.2
42.36°C
0.990
12.058V
5.030V
3.320V
4.939V
353.076
47.73°C
115.11V
6
27.373A
5.974A
5.980A
2.000A
389.369
91.005%
477
13.0
42.53°C
0.992
12.045V
5.023V
3.312V
4.924V
427.853
48.50°C
115.11V
7
32.057A
6.982A
6.995A
2.243A
454.843
90.506%
653
16.3
43.21°C
0.994
12.032V
5.015V
3.304V
4.907V
502.553
49.63°C
115.11V
8
36.751A
7.993A
8.013A
2.454A
520.129
90.010%
772
21.4
43.68°C
0.995
12.019V
5.006V
3.295V
4.891V
577.858
51.08°C
115.11V
9
41.861A
8.502A
8.515A
2.458A
585.052
89.525%
905
23.4
44.37°C
0.995
12.005V
5.000V
3.288V
4.883V
653.504
52.51°C
115.10V
10
46.717A
9.017A
9.056A
3.093A
649.903
88.925%
1026
27.3
45.52°C
0.995
11.991V
4.992V
3.280V
4.851V
730.841
54.66°C
115.10V
11
52.184A
9.027A
9.072A
3.097A
714.732
88.303%
1137
30.7
46.84°C
0.995
11.977V
4.987V
3.274V
4.845V
809.412
56.70°C
115.10V
CL1
0.104A
14.004A
13.999A
0.000A
118.106
84.674%
553
14.5
42.27°C
0.972
12.095V
5.028V
3.317V
5.003V
139.483
47.50°C
115.12V
CL2
54.098A
1.000A
1.001A
1.000A
661.851
89.694%
1045
27.4
45.87°C
0.995
11.989V
5.016V
3.304V
4.946V
737.900
54.52°C
115.10V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.581A
1.977A
1.970A
1.000A
64.961
87.957%
238
7.0
40.25°C
0.872
12.109V
5.058V
3.351V
4.998V
73.855
43.21°C
230.23V
2
8.194A
2.970A
2.961A
1.204A
130.020
92.026%
240
7.1
40.33°C
0.940
12.097V
5.051V
3.342V
4.983V
141.286
44.16°C
230.23V
3
13.154A
3.470A
3.465A
1.409A
195.033
93.373%
241
7.1
41.55°C
0.961
12.085V
5.045V
3.336V
4.969V
208.876
45.97°C
230.23V
4
18.127A
3.970A
3.968A
1.615A
260.046
93.835%
243
7.2
41.68°C
0.971
12.072V
5.039V
3.329V
4.955V
277.131
46.64°C
230.24V
5
22.770A
4.969A
4.969A
1.823A
325.088
93.887%
246
7.2
42.16°C
0.978
12.059V
5.031V
3.321V
4.939V
346.254
47.58°C
230.23V
6
27.370A
5.973A
5.979A
2.000A
389.364
93.036%
519
14.7
42.62°C
0.982
12.046V
5.024V
3.313V
4.924V
418.508
48.87°C
230.24V
7
32.053A
6.978A
6.993A
2.242A
454.841
92.807%
664
17.7
43.19°C
0.984
12.034V
5.017V
3.304V
4.907V
490.096
49.87°C
230.24V
8
36.744A
7.992A
8.011A
2.454A
520.125
92.564%
763
21.6
43.98°C
0.986
12.021V
5.007V
3.296V
4.892V
561.908
51.45°C
230.24V
9
41.847A
8.500A
8.514A
2.458A
585.016
92.412%
865
24.1
44.86°C
0.988
12.008V
5.001V
3.289V
4.884V
633.051
52.83°C
230.25V
10
46.694A
9.013A
9.054A
3.092A
649.808
92.119%
966
26.1
45.39°C
0.989
11.995V
4.993V
3.281V
4.853V
705.399
54.12°C
230.24V
11
52.164A
9.024A
9.069A
3.096A
714.684
91.844%
1122
29.9
45.69°C
0.991
11.981V
4.988V
3.274V
4.846V
778.150
55.47°C
230.24V
CL1
0.101A
14.003A
13.998A
0.000A
118.103
86.036%
534
15.0
42.44°C
0.937
12.096V
5.030V
3.318V
5.003V
137.271
47.57°C
230.24V
CL2
54.098A
1.000A
1.001A
1.000A
662.068
92.891%
1036
27.4
45.74°C
0.990
11.993V
5.017V
3.304V
4.947V
712.736
54.08°C
230.23V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.225A
0.494A
0.490A
0.199A
19.991
74.022%
230
6.7
0.897
12.117V
5.063V
3.357V
5.035V
27.007
115.11V
2
2.450A
0.989A
0.984A
0.398A
39.981
82.907%
232
6.8
0.940
12.113V
5.060V
3.354V
5.025V
48.224
115.11V
3
3.680A
1.483A
1.477A
0.598A
60.012
86.905%
236
7.0
0.961
12.109V
5.057V
3.352V
5.015V
69.055
115.11V
4
4.904A
1.978A
1.972A
0.799A
79.964
88.586%
235
7.0
0.963
12.105V
5.055V
3.349V
5.004V
90.267
115.11V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.224A
0.494A
0.492A
0.199A
19.987
74.581%
233
6.9
0.622
12.118V
5.063V
3.358V
5.035V
26.799
230.22V
2
2.450A
0.987A
0.984A
0.398A
39.976
84.261%
234
6.9
0.781
12.114V
5.061V
3.355V
5.025V
47.443
230.23V
3
3.679A
1.483A
1.477A
0.598A
60.008
87.874%
235
7.0
0.859
12.110V
5.059V
3.353V
5.015V
68.289
230.22V
4
4.903A
1.978A
1.971A
0.799A
79.960
89.825%
237
7.0
0.898
12.106V
5.057V
3.350V
5.005V
89.018
230.23V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
8.10mV
7.70mV
16.50mV
3.70mV
Pass
20% Load
10.40mV
7.90mV
17.10mV
3.90mV
Pass
30% Load
12.50mV
7.80mV
17.20mV
4.10mV
Pass
40% Load
13.80mV
7.60mV
20.20mV
4.00mV
Pass
50% Load
15.90mV
8.20mV
19.70mV
3.90mV
Pass
60% Load
30.40mV
12.80mV
28.20mV
4.50mV
Pass
70% Load
29.60mV
12.00mV
31.10mV
4.60mV
Pass
80% Load
26.00mV
14.50mV
25.30mV
5.20mV
Pass
90% Load
21.80mV
16.60mV
34.20mV
5.70mV
Pass
100% Load
29.30mV
18.00mV
31.60mV
8.50mV
Pass
110% Load
29.10mV
17.80mV
36.00mV
9.40mV
Pass
Crossload1
15.70mV
10.40mV
24.90mV
7.40mV
Pass
Crossload2
28.30mV
17.60mV
25.60mV
6.10mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
7.90mV
7.40mV
14.50mV
3.80mV
Pass
20% Load
11.40mV
7.30mV
15.50mV
3.90mV
Pass
30% Load
13.10mV
7.20mV
17.60mV
3.80mV
Pass
40% Load
14.80mV
7.60mV
20.40mV
4.20mV
Pass
50% Load
17.20mV
7.80mV
23.80mV
4.40mV
Pass
60% Load
34.60mV
12.10mV
27.90mV
4.30mV
Pass
70% Load
32.30mV
13.80mV
27.80mV
4.30mV
Pass
80% Load
29.40mV
13.40mV
27.20mV
5.20mV
Pass
90% Load
24.20mV
14.20mV
33.80mV
6.70mV
Pass
100% Load
31.20mV
16.30mV
30.70mV
8.30mV
Pass
110% Load
30.40mV
17.50mV
32.80mV
8.60mV
Pass
Crossload1
16.10mV
10.40mV
24.40mV
7.20mV
Pass
Crossload2
29.30mV
16.70mV
27.00mV
6.20mV
Pass
The results above are not used in the certification process
be quiet! Straight Power 11 Platinum 650W
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted