This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.230
66.092%
0.036
5.120V
0.348
115.10V
2
0.090A
0.461
72.828%
0.065
5.119V
0.633
115.11V
3
0.550A
2.809
80.556%
0.272
5.107V
3.487
115.11V
4
1.000A
5.096
80.761%
0.367
5.096V
6.310
115.11V
5
1.500A
7.625
80.517%
0.420
5.083V
9.470
115.11V
6
3.000A
15.138
79.331%
0.493
5.046V
19.082
115.11V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.230
58.673%
0.012
5.120V
0.392
230.25V
2
0.090A
0.461
67.595%
0.021
5.119V
0.682
230.24V
3
0.550A
2.809
78.508%
0.106
5.107V
3.578
230.23V
4
1.000A
5.096
80.227%
0.174
5.096V
6.352
230.22V
5
1.500A
7.626
79.870%
0.234
5.083V
9.548
230.22V
6
3.001A
15.138
80.044%
0.337
5.045V
18.912
230.22V
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
6.370A
1.962A
1.959A
1.006A
100.006
91.091%
0
<6.0
43.26°C
0.972
12.309V
5.097V
3.368V
4.969V
109.787
40.64°C
115.11V
2
13.741A
2.945A
2.942A
1.211A
200.040
93.201%
0
<6.0
44.78°C
0.988
12.309V
5.094V
3.365V
4.956V
214.633
41.12°C
115.10V
3
21.443A
3.436A
3.436A
1.416A
300.014
93.867%
0
<6.0
45.53°C
0.995
12.310V
5.092V
3.363V
4.943V
319.617
41.52°C
115.10V
4
29.127A
3.930A
3.928A
1.623A
399.672
93.542%
636
20.1
41.76°C
0.995
12.307V
5.090V
3.361V
4.930V
427.263
47.20°C
115.10V
5
36.516A
4.914A
4.915A
1.831A
499.807
93.161%
652
20.9
42.21°C
0.994
12.304V
5.088V
3.359V
4.917V
536.496
48.27°C
115.10V
6
43.889A
5.902A
5.901A
2.000A
599.724
92.713%
707
23.7
43.29°C
0.995
12.306V
5.085V
3.356V
4.905V
646.860
49.85°C
115.09V
7
51.234A
6.889A
6.890A
2.250A
699.658
92.142%
781
27.0
43.42°C
0.996
12.307V
5.082V
3.354V
4.890V
759.326
50.39°C
115.09V
8
58.643A
7.878A
7.876A
2.461A
800.183
91.569%
857
29.8
44.96°C
0.997
12.308V
5.079V
3.351V
4.876V
873.859
52.72°C
115.09V
9
66.370A
8.371A
8.359A
2.465A
899.455
90.958%
939
32.1
45.24°C
0.997
12.309V
5.077V
3.350V
4.870V
988.866
53.48°C
115.08V
10
73.938A
8.868A
8.873A
3.096A
999.880
90.208%
1012
35.2
45.40°C
0.998
12.310V
5.075V
3.347V
4.845V
1108.417
54.53°C
115.08V
11
82.056A
8.872A
8.878A
3.100A
1099.896
89.433%
1443
43.8
46.53°C
0.998
12.311V
5.073V
3.345V
4.839V
1229.849
56.42°C
115.08V
CL1
0.101A
15.002A
14.997A
0.000A
127.741
88.643%
839
29.2
42.75°C
0.980
12.339V
5.077V
3.356V
5.010V
144.108
48.69°C
115.11V
CL2
83.008A
1.000A
1.000A
1.000A
1034.919
90.329%
1010
35.2
45.65°C
0.998
12.307V
5.084V
3.352V
4.905V
1145.728
54.22°C
115.08V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
6.368A
1.962A
1.962A
1.006A
100.007
92.043%
0
<6.0
42.80°C
0.822
12.312V
5.097V
3.367V
4.969V
108.652
39.84°C
230.24V
2
13.739A
2.944A
2.942A
1.211A
200.038
94.459%
0
<6.0
44.47°C
0.921
12.311V
5.094V
3.365V
4.955V
211.772
40.77°C
230.24V
3
21.448A
3.437A
3.434A
1.416A
300.012
95.006%
632
20.1
41.46°C
0.953
12.307V
5.093V
3.363V
4.943V
315.781
45.76°C
230.24V
4
29.133A
3.927A
3.926A
1.623A
399.670
95.106%
636
20.1
41.62°C
0.967
12.305V
5.091V
3.361V
4.930V
420.237
46.55°C
230.24V
5
36.511A
4.913A
4.913A
1.831A
499.802
94.942%
670
23.1
42.09°C
0.975
12.306V
5.088V
3.358V
4.917V
526.427
47.87°C
230.23V
6
43.894A
5.901A
5.904A
2.000A
599.739
94.712%
724
24.5
42.57°C
0.981
12.305V
5.085V
3.355V
4.905V
633.225
48.85°C
230.23V
7
51.238A
6.888A
6.891A
2.250A
699.654
94.378%
783
27.0
43.42°C
0.984
12.306V
5.083V
3.353V
4.890V
741.333
50.29°C
230.23V
8
58.646A
7.878A
7.878A
2.461A
800.179
94.012%
853
29.8
43.65°C
0.987
12.307V
5.080V
3.351V
4.877V
851.149
51.11°C
230.24V
9
66.379A
8.372A
8.360A
2.465A
899.442
93.662%
925
32.2
44.22°C
0.989
12.307V
5.078V
3.349V
4.870V
960.302
52.50°C
230.23V
10
73.943A
8.869A
8.872A
3.096A
999.873
93.194%
1005
34.2
45.25°C
0.990
12.309V
5.075V
3.347V
4.846V
1072.891
54.31°C
230.24V
11
82.062A
8.869A
8.879A
3.100A
1099.889
92.750%
1316
41.6
46.55°C
0.991
12.310V
5.074V
3.345V
4.840V
1185.863
56.34°C
230.23V
CL1
0.101A
15.000A
14.998A
0.000A
127.749
89.546%
814
28.4
42.16°C
0.873
12.335V
5.077V
3.357V
5.009V
142.663
47.51°C
230.25V
CL2
83.018A
1.000A
1.001A
1.000A
1035.050
93.422%
1008
35.2
45.61°C
0.990
12.307V
5.085V
3.352V
4.906V
1107.930
54.81°C
230.24V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.207A
0.489A
0.488A
0.200A
19.991
76.606%
0
<6.0
0.810
12.303V
5.106V
3.373V
4.997V
26.096
115.11V
2
2.412A
0.981A
0.979A
0.401A
39.981
85.104%
0
<6.0
0.911
12.304V
5.101V
3.370V
4.990V
46.979
115.11V
3
3.622A
1.471A
1.467A
0.602A
60.012
88.426%
0
<6.0
0.946
12.305V
5.099V
3.369V
4.983V
67.867
115.11V
4
4.823A
1.962A
1.959A
0.804A
79.963
90.332%
0
<6.0
0.964
12.308V
5.098V
3.368V
4.976V
88.521
115.11V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.206A
0.490A
0.489A
0.200A
19.994
76.708%
0
<6.0
0.463
12.308V
5.105V
3.373V
4.997V
26.065
230.25V
2
2.412A
0.979A
0.980A
0.401A
39.985
85.518%
0
<6.0
0.629
12.309V
5.100V
3.369V
4.990V
46.756
230.25V
3
3.620A
1.472A
1.469A
0.602A
60.014
89.090%
0
<6.0
0.718
12.310V
5.098V
3.368V
4.983V
67.363
230.25V
4
4.822A
1.962A
1.961A
0.804A
79.964
90.896%
0
<6.0
0.784
12.310V
5.097V
3.368V
4.976V
87.973
230.25V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
9.20mV
6.40mV
12.20mV
3.60mV
Pass
20% Load
11.60mV
6.50mV
12.80mV
4.10mV
Pass
30% Load
11.00mV
7.00mV
14.20mV
4.50mV
Pass
40% Load
8.60mV
7.40mV
13.90mV
5.20mV
Pass
50% Load
8.50mV
8.00mV
15.50mV
5.40mV
Pass
60% Load
8.90mV
7.40mV
14.90mV
5.90mV
Pass
70% Load
9.70mV
7.50mV
15.70mV
6.50mV
Pass
80% Load
10.60mV
8.70mV
16.40mV
6.60mV
Pass
90% Load
11.30mV
8.20mV
16.30mV
7.20mV
Pass
100% Load
18.00mV
8.50mV
17.20mV
9.00mV
Pass
110% Load
18.90mV
8.90mV
17.10mV
9.30mV
Pass
Crossload1
13.50mV
9.00mV
18.80mV
4.30mV
Pass
Crossload2
18.30mV
7.80mV
13.80mV
8.80mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
9.30mV
6.40mV
13.30mV
3.50mV
Pass
20% Load
11.50mV
6.90mV
12.90mV
4.20mV
Pass
30% Load
10.60mV
6.80mV
15.00mV
4.20mV
Pass
40% Load
7.90mV
8.00mV
14.70mV
4.70mV
Pass
50% Load
8.10mV
8.00mV
15.20mV
5.60mV
Pass
60% Load
9.10mV
7.70mV
15.40mV
6.10mV
Pass
70% Load
9.40mV
7.40mV
15.50mV
6.40mV
Pass
80% Load
10.40mV
7.80mV
16.00mV
6.50mV
Pass
90% Load
11.00mV
8.10mV
16.60mV
7.00mV
Pass
100% Load
17.10mV
9.00mV
17.50mV
8.40mV
Pass
110% Load
18.50mV
8.90mV
17.60mV
9.10mV
Pass
Crossload1
13.90mV
8.90mV
16.30mV
4.20mV
Pass
Crossload2
17.70mV
7.70mV
13.90mV
8.30mV
Pass
The results above are not used in the certification process
Antec Signature Titanium 1000W
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted