ErP Lot 6 2010: ✓
ErP Lot 6 2013: ✓
ErP Lot 3 2014 & CEC: Partially
(EU) No 617/2013 Compliance
✓
ALPM (Alternative Low Power Mode) compatible
✓
Performance Summary
Efficiency Rating
GOLD
Noise Rating
A-
Average Efficiency (>1450 load combinations)
88.654%
Average Noise Output (>1450 Load Combinations)
28.05dBA
Average PF (>1450 Load Combinations)
0.986
Efficiency With 10W (≤500W) or 2% (>500W) Load
52.344%
Standby Power Consumption
0.0869W
12V Ripple (Full Load)
47.14mV
5V Ripple (Full Load)
6.98mV
3.3V Ripple (Full Load)
18.68mV
5VSB Ripple (Full Load)
9.54mV
12V Load Regulation
0.83%
5V Load Regulation
1.81%
3.3V Load Regulation
2.39%
5VSB Load Regulation
3.01%
Inrush Current
26.490A
Efficiency Rating
GOLD
Noise Rating
A-
Average Efficiency (>1450 load combinations)
90.577%
Average Noise Output (>1450 Load Combinations)
29.70dBA
Average PF (>1450 Load Combinations)
0.930
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.1350W
12V Ripple (Full Load)
49.39mV
5V Ripple (Full Load)
7.04mV
3.3V Ripple (Full Load)
17.19mV
5VSB Ripple (Full Load)
10.10mV
12V Load Regulation
0.81%
5V Load Regulation
1.73%
3.3V Load Regulation
2.36%
5VSB Load Regulation
2.96%
Inrush Current
75.320A
12V Transient Response (150%)
0.00V
5V Transient Response (150%)
V
3.3V Transient Response (150%)
V
5VSB Transient Response (150%)
V
Hold-Up Time & Power Ok Signal
18.50ms
AC Loss to PWR_OK Hold Up Time
14.70ms
PWR_OK Inactive to DC Loss Delay
3.80ms
PSU Timings: T1 (20% / 100%)
52.0ms
52.0ms
PSU Timings: T3 (20% / 100%)
134.0ms
134.0ms
OPP (0.00°C / 0.00°C)
124.16%
0.00%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
18.5
AC Loss to PWR_OK Hold Up Time (ms)
14.7
PWR_OK Inactive to DC Loss Delay (ms)
3.8
Vampire Power
Tables
Graphs
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.230
69.697%
0.043
5.119V
0.330
115.14V
2
0.090A
0.461
73.175%
0.080
5.117V
0.630
115.14V
3
0.550A
2.808
77.698%
0.312
5.105V
3.614
115.14V
4
1.000A
5.094
80.563%
0.394
5.093V
6.323
115.15V
5
1.500A
7.621
80.441%
0.441
5.079V
9.474
115.15V
6
3.000A
15.117
78.632%
0.497
5.039V
19.225
115.14V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.230
57.644%
0.016
5.118V
0.399
230.33V
2
0.090A
0.461
65.205%
0.028
5.117V
0.707
230.33V
3
0.550A
2.808
74.940%
0.134
5.105V
3.747
230.36V
4
1.000A
5.094
78.177%
0.208
5.093V
6.516
230.36V
5
1.500A
7.620
79.226%
0.268
5.079V
9.618
230.35V
6
3.001A
15.117
79.921%
0.360
5.038V
18.915
230.34V
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
2.342A
1.993A
1.951A
0.984A
50.002
81.255%
773
14.8
40.10°C
0.952
12.124V
5.021V
3.382V
5.083V
61.537
42.98°C
115.16V
2
5.706A
2.994A
2.936A
1.184A
100.027
87.087%
779
14.9
40.23°C
0.980
12.113V
5.011V
3.373V
5.070V
114.859
43.97°C
115.16V
3
9.414A
3.498A
3.432A
1.384A
149.983
89.185%
784
15.1
41.07°C
0.987
12.103V
5.002V
3.365V
5.058V
168.170
45.15°C
115.14V
4
13.133A
4.005A
3.933A
1.586A
200.024
89.652%
1446
33.1
41.74°C
0.985
12.093V
4.994V
3.357V
5.046V
223.111
46.55°C
115.13V
5
16.516A
5.018A
4.927A
1.789A
250.054
89.746%
1798
40.0
42.39°C
0.987
12.082V
4.984V
3.348V
5.032V
278.623
47.71°C
115.13V
6
19.898A
6.034A
5.931A
1.993A
300.007
89.751%
1808
40.0
42.43°C
0.990
12.071V
4.974V
3.339V
5.018V
334.266
48.53°C
115.13V
7
23.298A
7.054A
6.936A
2.199A
350.083
89.519%
1820
40.0
43.21°C
0.992
12.060V
4.963V
3.330V
5.004V
391.072
49.86°C
115.13V
8
26.702A
8.003A
7.950A
2.405A
399.748
89.187%
1823
40.0
43.70°C
0.993
12.048V
4.953V
3.321V
4.990V
448.215
50.82°C
115.12V
9
30.512A
8.598A
8.451A
2.409A
449.815
88.837%
1824
40.0
44.65°C
0.994
12.038V
4.944V
3.313V
4.983V
506.337
52.48°C
115.12V
10
34.099A
9.121A
8.989A
3.026A
499.832
88.303%
1832
39.9
45.35°C
0.995
12.027V
4.935V
3.305V
4.958V
566.040
53.39°C
115.12V
11
38.291A
9.134A
9.007A
3.030A
549.855
87.872%
1833
39.9
46.63°C
0.995
12.017V
4.927V
3.298V
4.952V
625.744
55.42°C
115.13V
CL1
0.117A
11.999A
12.000A
0.000A
101.443
82.277%
1811
40.0
42.30°C
0.985
12.099V
4.986V
3.350V
5.082V
123.295
47.29°C
115.16V
CL2
41.009A
1.001A
1.000A
1.000A
507.030
89.391%
1824
40.0
45.92°C
0.995
12.039V
4.959V
3.327V
5.032V
567.206
53.76°C
115.12V
The results above are not used in the certification process
est #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
2.342A
1.992A
1.952A
0.984A
49.996
82.543%
776
14.8
40.72°C
0.738
12.123V
5.021V
3.382V
5.083V
60.570
44.32°C
230.29V
2
5.706A
2.994A
2.934A
1.184A
100.014
88.593%
782
15.0
40.85°C
0.857
12.112V
5.011V
3.373V
5.070V
112.892
44.75°C
230.28V
3
9.414A
3.499A
3.432A
1.384A
149.970
90.634%
787
15.1
41.55°C
0.910
12.101V
5.002V
3.365V
5.058V
165.467
45.89°C
230.30V
4
13.134A
4.005A
3.932A
1.586A
200.009
91.326%
1400
32.9
41.88°C
0.937
12.091V
4.994V
3.358V
5.045V
219.006
46.80°C
230.30V
5
16.517A
5.018A
4.928A
1.789A
250.042
91.391%
1806
40.0
42.19°C
0.952
12.080V
4.984V
3.349V
5.032V
273.595
47.63°C
230.31V
6
19.901A
6.034A
5.932A
1.993A
300.000
91.563%
1816
40.0
42.57°C
0.962
12.069V
4.973V
3.339V
5.018V
327.644
48.61°C
230.31V
7
23.300A
7.055A
6.938A
2.199A
350.073
91.535%
1824
40.0
43.20°C
0.968
12.058V
4.963V
3.330V
5.004V
382.448
49.81°C
230.32V
8
26.706A
8.001A
7.950A
2.405A
399.725
91.418%
1824
40.0
43.40°C
0.973
12.046V
4.953V
3.320V
4.990V
437.250
50.40°C
230.32V
9
30.516A
8.598A
8.451A
2.409A
449.801
91.304%
1834
39.9
45.30°C
0.977
12.036V
4.944V
3.313V
4.983V
492.641
52.82°C
230.32V
10
34.107A
9.120A
8.989A
3.026A
499.846
91.039%
1835
39.9
45.44°C
0.978
12.025V
4.935V
3.304V
4.958V
549.045
53.70°C
230.32V
11
38.300A
9.134A
9.007A
3.030A
549.878
90.894%
1841
39.9
46.59°C
0.980
12.015V
4.927V
3.297V
4.952V
604.963
55.35°C
230.33V
CL1
0.117A
12.000A
11.999A
0.000A
101.443
83.653%
1824
40.0
42.28°C
0.869
12.098V
4.986V
3.350V
5.081V
121.267
47.80°C
230.34V
CL2
41.013A
1.000A
0.999A
1.000A
507.025
92.103%
1833
39.9
45.40°C
0.978
12.038V
4.958V
3.326V
5.031V
550.495
53.64°C
230.34V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.224A
0.497A
0.487A
0.196A
19.991
66.371%
751
13.8
0.863
12.121V
5.032V
3.391V
5.112V
30.120
115.16V
2
2.448A
0.994A
0.973A
0.392A
39.981
79.639%
758
14.1
0.939
12.128V
5.026V
3.386V
5.103V
50.203
115.16V
3
3.675A
1.494A
1.464A
0.589A
60.010
83.979%
769
14.6
0.967
12.124V
5.021V
3.382V
5.094V
71.458
115.16V
4
4.898A
1.994A
1.953A
0.787A
79.959
86.191%
772
14.8
0.981
12.119V
5.016V
3.378V
5.085V
92.770
115.16V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.223A
0.496A
0.487A
0.196A
19.984
69.505%
744
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
20.50mV
4.00mV
12.60mV
6.40mV
Pass
20% Load
30.70mV
4.20mV
12.70mV
6.80mV
Pass
30% Load
41.30mV
4.40mV
12.40mV
6.40mV
Pass
40% Load
48.20mV
4.90mV
13.00mV
6.40mV
Pass
50% Load
50.20mV
5.20mV
15.10mV
7.10mV
Pass
60% Load
41.40mV
4.90mV
13.60mV
7.30mV
Pass
70% Load
37.50mV
5.10mV
13.70mV
7.50mV
Pass
80% Load
33.90mV
5.10mV
14.60mV
7.30mV
Pass
90% Load
33.60mV
6.00mV
17.00mV
8.10mV
Pass
100% Load
47.10mV
7.00mV
18.70mV
9.50mV
Pass
110% Load
48.80mV
7.30mV
18.90mV
9.70mV
Pass
Crossload1
39.00mV
5.90mV
17.50mV
7.40mV
Pass
Crossload2
45.30mV
6.10mV
14.30mV
8.70mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
27.10mV
4.20mV
11.50mV
6.90mV
Pass
20% Load
40.80mV
4.10mV
12.40mV
7.30mV
Pass
30% Load
50.60mV
5.00mV
12.70mV
6.90mV
Pass
40% Load
56.60mV
5.00mV
13.00mV
7.30mV
Pass
50% Load
58.60mV
4.90mV
13.10mV
7.00mV
Pass
60% Load
49.20mV
4.90mV
12.70mV
7.50mV
Pass
70% Load
42.30mV
5.40mV
13.00mV
7.70mV
Pass
80% Load
39.10mV
5.70mV
15.90mV
8.30mV
Pass
90% Load
36.80mV
6.30mV
17.90mV
8.60mV
Pass
100% Load
49.40mV
7.00mV
17.20mV
10.10mV
Pass
110% Load
50.70mV
7.30mV
18.00mV
10.20mV
Pass
Crossload1
46.70mV
6.20mV
18.30mV
7.80mV
Pass
Crossload2
47.20mV
6.40mV
14.50mV
8.90mV
Pass
The results above are not used in the certification process
Kolink Enclave 500W (#2)
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted