ErP Lot 3/6 2010: ✓
ErP Lot 3/6 2013: ✓
ErP Lot 3/6 2014, CEC: Partially
(EU) No 617/2013 Compliance
✓
Performance Summary
Efficiency Rating
PLATINUM
Noise Rating
A+
Average Efficiency (>1450 load combinations)
90.579%
Average Noise Output (>1450 Load Combinations)
17.22dBA
Average PF (>1450 Load Combinations)
0.988
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.0727W
12V Ripple (Full Load)
24.52mV
5V Ripple (Full Load)
12.30mV
3.3V Ripple (Full Load)
13.17mV
5VSB Ripple (Full Load)
22.95mV
12V Load Regulation
0.61%
5V Load Regulation
0.61%
3.3V Load Regulation
0.87%
5VSB Load Regulation
1.82%
Inrush Current
37.526A
Efficiency Rating
PLATINUM
Noise Rating
A+
Average Efficiency (>1450 load combinations)
92.214%
Average Noise Output (>1450 Load Combinations)
16.21dBA
Average PF (>1450 Load Combinations)
0.953
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.1312W
12V Ripple (Full Load)
22.50mV
5V Ripple (Full Load)
11.02mV
3.3V Ripple (Full Load)
15.41mV
5VSB Ripple (Full Load)
22.48mV
12V Load Regulation
0.53%
5V Load Regulation
0.45%
3.3V Load Regulation
0.87%
5VSB Load Regulation
1.76%
Inrush Current
51.932A
Hold-Up Time & Power Ok Signal
17.90ms
AC Loss to PWR_OK Hold Up Time
15.60ms
PWR_OK Inactive to DC Loss Delay
2.30ms
PSU Timings: T1 (20% / 100%)
0.0ms
0.0ms
PSU Timings: T3 (20% / 100%)
0.0ms
0.0ms
OPP (0.00°C / 0.00°C)
0.00%
0.00%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
17.9
AC Loss to PWR_OK Hold Up Time (ms)
15.6
PWR_OK Inactive to DC Loss Delay (ms)
2.3
Vampire Power
Tables
Graphs
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.041A
0.207
64.486%
0.025
5.031V
0.321
115.21V
2
0.086A
0.435
72.379%
0.047
5.030V
0.601
115.21V
3
0.541A
2.713
80.029%
0.222
5.013V
3.390
115.20V
4
1.001A
5.003
80.929%
0.323
4.997V
6.182
115.20V
5
1.501A
7.475
80.290%
0.386
4.980V
9.310
115.20V
6
3.001A
14.786
77.809%
0.467
4.927V
19.003
115.20V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.041A
0.207
55.200%
0.009
5.031V
0.375
230.48V
2
0.087A
0.435
65.120%
0.016
5.029V
0.668
230.48V
3
0.541A
2.713
74.738%
0.083
5.011V
3.630
230.48V
4
1.001A
5.003
78.874%
0.138
4.996V
6.343
230.48V
5
1.501A
7.473
79.306%
0.192
4.979V
9.423
230.47V
6
3.001A
14.782
78.328%
0.301
4.926V
18.872
230.48V
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
4.359A
1.954A
1.968A
0.980A
74.725
88.784%
0
| 6
42.31°C
0.966
12.194V
5.115V
3.351V
5.084V
84.165
38.14°C
115.21V
2
9.747A
2.929A
2.954A
1.180A
149.704
92.985%
0
| 6
43.41°C
0.983
12.194V
5.110V
3.348V
5.078V
160.998
38.57°C
115.20V
3
15.490A
3.427A
3.464A
1.379A
224.837
93.174%
0
| 6
43.71°C
0.985
12.186V
5.106V
3.345V
5.070V
241.309
38.74°C
115.20V
4
21.229A
3.915A
3.946A
1.579A
299.693
92.840%
0
| 6
44.08°C
0.985
12.178V
5.104V
3.343V
5.062V
322.805
39.01°C
115.20V
5
26.641A
4.907A
4.938A
1.780A
374.731
92.356%
0
| 6
44.68°C
0.990
12.170V
5.099V
3.340V
5.054V
405.745
39.46°C
115.21V
6
32.052A
5.884A
5.932A
1.979A
449.588
91.163%
395
6.5
40.82°C
0.992
12.162V
5.097V
3.336V
5.049V
493.171
48.60°C
115.21V
7
37.479A
6.874A
6.931A
2.180A
524.590
90.559%
395
6.5
41.67°C
0.993
12.153V
5.094V
3.333V
5.042V
579.283
49.83°C
115.22V
8
42.915A
7.860A
7.929A
2.380A
599.557
89.664%
1025
27.8
43.08°C
0.994
12.144V
5.091V
3.329V
5.036V
668.674
51.35°C
115.22V
9
48.782A
8.357A
8.446A
2.380A
674.605
89.004%
1045
28.2
43.81°C
0.995
12.136V
5.088V
3.325V
5.035V
757.945
52.33°C
115.22V
10
54.404A
8.855A
8.933A
2.991A
749.443
88.191%
1045
28.2
45.08°C
0.996
12.127V
5.084V
3.323V
5.009V
849.795
54.30°C
115.22V
11
60.611A
8.861A
8.940A
2.995A
824.307
87.446%
1045
28.2
46.19°C
0.996
12.120V
5.081V
3.321V
5.005V
942.652
56.50°C
115.22V
CL1
0.098A
14.029A
14.004A
0.000A
119.418
86.951%
395
6.5
44.44°C
0.977
12.196V
5.097V
3.336V
5.154V
137.339
52.98°C
115.22V
CL2
61.934A
1.004A
1.001A
1.001A
764.956
88.462%
1045
28.2
45.68°C
0.996
12.133V
5.091V
3.332V
5.060V
864.731
54.39°C
115.22V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
4.365A
1.953A
1.966A
0.981A
74.804
88.602%
0
<6.0
46.10°C
0.824
12.197V
5.115V
3.350V
5.084V
84.427
38.93°C
365.12V
2
9.749A
2.927A
2.954A
1.181A
149.781
93.280%
0
<6.0
47.56°C
0.919
12.199V
5.113V
3.348V
5.078V
160.572
39.66°C
230.24V
3
15.489A
3.425A
3.466A
1.380A
224.912
94.012%
0
<6.0
48.89°C
0.950
12.191V
5.108V
3.345V
5.071V
239.238
40.63°C
230.23V
4
21.222A
3.911A
3.948A
1.580A
299.748
94.125%
0
<6.0
49.32°C
0.964
12.185V
5.105V
3.343V
5.060V
318.456
40.86°C
230.23V
5
26.632A
4.896A
4.938A
1.780A
374.795
93.626%
395
6.5
41.85°C
0.971
12.178V
5.104V
3.338V
5.055V
400.310
50.78°C
230.22V
6
32.038A
5.879A
5.934A
1.980A
449.678
93.304%
395
6.5
42.03°C
0.977
12.170V
5.101V
3.335V
5.049V
481.947
51.33°C
230.22V
7
37.460A
6.866A
6.931A
2.180A
524.670
92.913%
395
6.5
43.48°C
0.978
12.162V
5.098V
3.331V
5.042V
564.692
53.17°C
230.22V
8
42.881A
7.855A
7.931A
2.380A
599.575
92.177%
1025
27.8
44.80°C
0.980
12.154V
5.096V
3.327V
5.035V
650.457
55.34°C
230.22V
9
48.754A
8.345A
8.454A
2.380A
674.712
91.751%
1025
27.8
45.28°C
0.982
12.145V
5.095V
3.323V
5.035V
735.373
56.12°C
230.23V
10
54.364A
8.838A
8.940A
2.991A
749.549
91.221%
1025
27.8
46.25°C
0.984
12.138V
5.092V
3.321V
5.010V
821.687
57.76°C
230.23V
11
60.566A
8.843A
8.949A
2.994A
824.482
90.735%
1025
27.8
46.93°C
0.985
12.132V
5.090V
3.318V
5.007V
908.669
58.60°C
230.24V
CL1
0.102A
14.025A
14.004A
0.004A
119.662
86.933%
395
6.5
42.49°C
0.906
12.191V
5.105V
3.342V
5.153V
137.648
51.86°C
230.25V
CL2
61.943A
1.000A
1.003A
1.002A
765.866
91.610%
1045
28.2
45.06°C
0.984
12.146V
5.097V
3.326V
5.063V
836.011
55.41°C
230.22V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
PF/AC Volts
1
1.193A
0.482A
0.473A
0.195A
19.599
77.155%
0
| 6
0.856
12.201V
5.112V
3.350V
5.102V
25.402
115.21V
2
2.415A
0.967A
0.982A
0.390A
39.685
82.903%
0
| 6
0.929
12.198V
5.115V
3.352V
5.100V
47.869
115.21V
3
3.640A
1.459A
1.487A
0.585A
59.822
87.283%
0
| 6
0.961
12.196V
5.115V
3.352V
5.096V
68.538
115.21V
4
4.849A
1.955A
1.968A
0.785A
79.754
89.683%
0
| 6
0.968
12.202V
5.113V
3.350V
5.092V
88.929
115.21V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.200A
0.480A
0.475A
0.195A
19.682
75.396%
0
<6.0
0.453
12.203V
5.110V
3.349V
5.102V
26.105
230.24V
2
2.418A
0.969A
0.983A
0.391A
39.749
83.561%
0
<6.0
0.671
12.201V
5.116V
3.351V
5.101V
47.569
230.24V
3
3.643A
1.459A
1.489A
0.586A
59.880
87.486%
0
<6.0
0.777
12.199V
5.116V
3.350V
5.097V
68.445
230.24V
4
4.859A
1.952A
1.969A
0.786A
79.847
89.096%
0
<6.0
0.836
12.197V
5.115V
3.350V
5.092V
89.619
230.24V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
9.6 mV
6.4 mV
6.6 mV
8.4 mV
Pass
20% Load
9.1 mV
7.1 mV
7.6 mV
11.4 mV
Pass
30% Load
10.6 mV
7.3 mV
8.0 mV
13.2 mV
Pass
40% Load
12.0 mV
8.8 mV
8.5 mV
14.2 mV
Pass
50% Load
13.9 mV
8.6 mV
11.0 mV
15.0 mV
Pass
60% Load
16.0 mV
9.4 mV
8.6 mV
16.3 mV
Pass
70% Load
17.8 mV
9.6 mV
9.7 mV
17.4 mV
Pass
80% Load
20.1 mV
10.4 mV
11.7 mV
18.9 mV
Pass
90% Load
21.6 mV
11.1 mV
13.6 mV
20.0 mV
Pass
100% Load
24.5 mV
12.3 mV
13.2 mV
23.0 mV
Pass
110% Load
26.7 mV
13.3 mV
13.8 mV
23.9 mV
Pass
Crossload 1
11.5 mV
8.5 mV
9.5 mV
12.0 mV
Pass
Crossload 2
24.8 mV
11.7 mV
12.3 mV
22.3 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
7.9 mV
5.7 mV
9.5 mV
6.6 mV
Pass
20% Load
10.4 mV
6.8 mV
10.6 mV
9.1 mV
Pass
30% Load
10.7 mV
6.8 mV
10.3 mV
11.6 mV
Pass
40% Load
11.7 mV
6.7 mV
10.7 mV
13.1 mV
Pass
50% Load
13.0 mV
7.6 mV
12.0 mV
14.0 mV
Pass
60% Load
14.8 mV
7.9 mV
12.0 mV
15.8 mV
Pass
70% Load
16.7 mV
8.6 mV
13.3 mV
16.8 mV
Pass
80% Load
19.2 mV
9.4 mV
18.1 mV
18.4 mV
Pass
90% Load
20.5 mV
9.7 mV
17.8 mV
19.9 mV
Pass
100% Load
22.5 mV
11.0 mV
15.4 mV
22.5 mV
Pass
110% Load
24.7 mV
11.5 mV
17.1 mV
23.4 mV
Pass
Crossload 1
25.4 mV
7.4 mV
11.8 mV
8.0 mV
Pass
Crossload 2
22.4 mV
10.1 mV
16.6 mV
21.6 mV
Pass
The results above are not used in the certification process
Aerocool ACP-750FP7
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted