Protechnic Electric MGA8012YS-A15 (80mm, 12V, 0.28A, Sleeve Bearing)
5VSB Circuit
Rectifier
1x A-Power AP03N70I-H FET (700V, 2.5A, 4.4 Ohm)
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary 115V
Efficiency Rating
GOLD
Noise Rating
A-
Average Efficiency (>1450 load combinations)
87.847%
Average Noise Output (>1450 Load Combinations)
29.14dBA
Average PF (>1450 Load Combinations)
0.992
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.1207W
12V Ripple (Full Load)
61.55mV
5V Ripple (Full Load)
39.36mV
3.3V Ripple (Full Load)
26.07mV
5VSB Ripple (Full Load)
14.06mV
12V Load Regulation
1.62%
5V Load Regulation
2.34%
3.3V Load Regulation
2.49%
5VSB Load Regulation
3.64%
Inrush Current
39.893A
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
21.7
AC Loss to PWR_OK Hold Up Time (ms)
17.5
PWR_OK Inactive to DC Loss Delay (ms)
4.2
Vampire Power
Tables 115V
Graphs 115V
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
115V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
115V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC) 115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.228
59.843%
0.035
5.063V
0.381
115.39V
2
0.090A
0.456
69.939%
0.059
5.063V
0.652
115.39V
3
0.550A
2.775
78.191%
0.256
5.044V
3.549
115.38V
4
1.000A
5.024
79.975%
0.351
5.024V
6.282
115.38V
5
1.500A
7.501
79.283%
0.409
5.000V
9.461
115.37V
6
2.499A
12.380
76.971%
0.463
4.953V
16.084
115.36V
Supplementary Tests (For Reference)
Typical Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
2.737A
1.966A
1.958A
0.998A
54.473
82.258%
1412
15.8
38.29°C
0.962
12.011V
5.087V
3.369V
5.011V
66.222
46.83°C
115.31V
2
6.547A
2.957A
2.947A
1.202A
109.366
87.493%
1412
15.8
38.60°C
0.980
11.984V
5.074V
3.359V
4.995V
125.000
48.55°C
115.23V
3
10.761A
3.456A
3.430A
1.406A
164.872
89.239%
1412
15.8
39.15°C
0.989
11.976V
5.064V
3.352V
4.979V
184.753
49.84°C
115.14V
4
14.908A
3.960A
3.946A
1.612A
219.690
89.562%
1594
20.0
39.39°C
0.995
11.972V
5.053V
3.345V
4.964V
245.293
51.52°C
115.16V
5
18.738A
4.962A
4.946A
1.820A
274.582
89.470%
1919
25.2
40.07°C
0.997
11.958V
5.040V
3.336V
4.948V
306.899
53.20°C
115.07V
6
22.577A
5.970A
5.952A
2.029A
329.510
89.145%
2265
30.2
40.84°C
0.998
11.946V
5.026V
3.326V
4.931V
369.632
55.27°C
114.99V
7
26.472A
6.983A
6.964A
2.240A
384.809
88.587%
2602
34.2
42.13°C
0.998
11.926V
5.012V
3.317V
4.913V
434.385
58.24°C
115.01V
8
30.402A
8.005A
7.983A
2.453A
440.109
87.845%
2957
38.4
42.55°C
0.999
11.897V
4.998V
3.307V
4.895V
501.004
61.20°C
114.92V
9
34.754A
8.522A
8.489A
2.457A
494.630
87.030%
3250
40.7
44.29°C
0.999
11.858V
4.988V
3.299V
4.886V
568.343
63.97°C
114.83V
10
39.131A
9.043A
9.027A
2.567A
549.744
85.951%
3460
42.2
45.73°C
0.999
11.820V
4.977V
3.291V
4.870V
639.602
66.99°C
114.84V
11
44.160A
9.055A
9.046A
2.572A
604.956
84.953%
3460
42.2
46.73°C
0.999
11.724V
4.971V
3.284V
4.862V
712.108
69.73°C
114.75V
CL1
0.737A
14.003A
13.999A
0.000A
125.036
82.678%
2745
35.6
44.38°C
0.985
11.993V
4.981V
3.318V
5.026V
151.233
58.28°C
115.19V
CL2
45.005A
1.002A
1.000A
1.000A
545.702
86.687%
3450
42.0
45.35°C
0.999
11.829V
5.046V
3.322V
4.960V
629.508
63.22°C
114.77V
The results above are not used in the certification process
Light Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.204A
0.490A
0.473A
0.198A
19.564
68.547%
1412
15.8
0.826
12.015V
5.101V
3.379V
5.054V
28.541
115.36V
2
2.465A
0.984A
0.978A
0.397A
39.934
79.834%
1412
15.8
0.939
12.015V
5.096V
3.375V
5.043V
50.021
115.33V
3
3.669A
1.473A
1.451A
0.597A
59.458
83.994%
1412
15.8
0.965
12.010V
5.090V
3.371V
5.031V
70.788
115.30V
4
4.937A
1.967A
1.961A
0.797A
79.862
86.137%
1412
15.8
0.972
12.003V
5.085V
3.366V
5.019V
92.715
115.27V
The results above are not used in the certification process
Ripple Measurements 115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
10.9 mV
15.9 mV
13.7 mV
11.5 mV
Pass
20% Load
28.6 mV
23.1 mV
15.5 mV
14.5 mV
Pass
30% Load
28.0 mV
22.7 mV
14.9 mV
7.8 mV
Pass
40% Load
29.2 mV
22.9 mV
15.6 mV
8.7 mV
Pass
50% Load
33.2 mV
25.5 mV
16.5 mV
9.3 mV
Pass
60% Load
33.9 mV
28.8 mV
18.9 mV
10.2 mV
Pass
70% Load
36.6 mV
32.1 mV
20.7 mV
10.6 mV
Pass
80% Load
38.0 mV
33.2 mV
20.9 mV
11.0 mV
Pass
90% Load
46.3 mV
36.5 mV
22.9 mV
12.3 mV
Pass
100% Load
61.6 mV
39.4 mV
26.1 mV
14.1 mV
Pass
110% Load
97.3 mV
41.8 mV
27.3 mV
15.2 mV
Pass
Crossload 1
33.4 mV
26.5 mV
18.7 mV
17.0 mV
Pass
Crossload 2
60.2 mV
38.3 mV
25.4 mV
18.2 mV
Pass
The results above are not used in the certification process
SilverStone SFX 550W
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted