ErP Lot 6 2010: ✓
ErP Lot 6 2013: Partially
ErP Lot 3 2014 & CEC: ✗
(EU) No 617/2013 Compliance
✓
Performance Summary
Efficiency Rating
SILVER
Noise Rating
A-
Average Efficiency (>1450 load combinations)
89.935%
Average Noise Output (>1450 Load Combinations)
27.53dBA
Average PF (>1450 Load Combinations)
0.980
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.1224W
12V Ripple (Full Load)
41.90mV
5V Ripple (Full Load)
18.94mV
3.3V Ripple (Full Load)
28.21mV
5VSB Ripple (Full Load)
15.73mV
12V Load Regulation
0.90%
5V Load Regulation
2.24%
3.3V Load Regulation
2.40%
5VSB Load Regulation
2.32%
Inrush Current
33.613A
Efficiency Rating
Noise Rating
A-
Average Efficiency (>1450 load combinations)
92.226%
Average Noise Output (>1450 Load Combinations)
27.12dBA
Average PF (>1450 Load Combinations)
0.931
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.2680W
12V Ripple (Full Load)
45.08mV
5V Ripple (Full Load)
17.98mV
3.3V Ripple (Full Load)
29.54mV
5VSB Ripple (Full Load)
15.73mV
12V Load Regulation
0.57%
5V Load Regulation
1.70%
3.3V Load Regulation
1.75%
5VSB Load Regulation
1.85%
Inrush Current
58.157A
12V Transient Response (150%)
0.00V
5V Transient Response (150%)
V
3.3V Transient Response (150%)
V
5VSB Transient Response (150%)
V
Hold-Up Time & Power Ok Signal
11.20ms
AC Loss to PWR_OK Hold Up Time
9.90ms
PWR_OK Inactive to DC Loss Delay
1.30ms
PSU Timings: T1 (20% / 100%)
0.0ms
0.0ms
PSU Timings: T3 (20% / 100%)
0.0ms
0.0ms
OPP (0.00°C / 0.00°C)
0.00%
0.00%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
11.2
AC Loss to PWR_OK Hold Up Time (ms)
9.9
PWR_OK Inactive to DC Loss Delay (ms)
1.3
Vampire Power
Tables
Graphs
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.214
53.500%
0.066
5.133V
0.400
115.13V
2
0.087A
0.447
63.494%
0.112
5.133V
0.704
115.13V
3
0.542A
2.779
73.772%
0.343
5.125V
3.767
115.10V
4
1.002A
5.125
74.730%
0.411
5.114V
6.858
115.11V
5
1.502A
7.661
74.263%
0.444
5.101V
10.316
115.12V
6
2.501A
12.700
72.642%
0.480
5.077V
17.483
115.12V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.215
38.949%
0.028
5.134V
0.552
230.27V
2
0.087A
0.448
51.376%
0.043
5.134V
0.872
230.30V
3
0.542A
2.780
68.983%
0.173
5.125V
4.030
230.28V
4
1.002A
5.126
72.493%
0.253
5.115V
7.071
230.29V
5
1.502A
7.663
73.910%
0.304
5.102V
10.368
230.29V
6
2.501A
12.702
73.982%
0.362
5.078V
17.169
230.29V
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.541A
1.934A
1.953A
0.979A
64.776
86.840%
930
25.1
38.11°C
0.939
12.204V
5.159V
3.374V
5.102V
74.592
40.55°C
115.15V
2
8.113A
2.918A
2.938A
1.175A
129.805
90.335%
930
25.1
38.45°C
0.962
12.193V
5.145V
3.365V
5.093V
143.693
41.12°C
115.16V
3
13.036A
3.405A
3.450A
1.376A
194.867
91.343%
930
25.1
39.02°C
0.976
12.182V
5.135V
3.358V
5.081V
213.335
42.26°C
115.15V
4
17.963A
3.902A
3.937A
1.575A
259.788
91.521%
930
25.1
39.45°C
0.984
12.170V
5.125V
3.351V
5.071V
283.857
43.46°C
115.15V
5
22.559A
4.890A
4.935A
1.775A
324.765
91.113%
1020
27.7
39.99°C
0.988
12.159V
5.113V
3.341V
5.059V
356.441
44.68°C
115.15V
6
27.167A
5.882A
5.937A
1.980A
389.769
90.595%
1230
33.6
40.22°C
0.990
12.147V
5.098V
3.333V
5.049V
430.232
45.60°C
115.15V
7
31.775A
6.886A
6.947A
2.180A
454.662
89.911%
1395
38.3
41.55°C
0.992
12.135V
5.084V
3.323V
5.036V
505.681
47.37°C
115.15V
8
36.397A
7.893A
7.965A
2.386A
519.643
89.151%
1550
39.8
42.58°C
0.993
12.123V
5.070V
3.314V
5.025V
582.877
48.93°C
115.15V
9
41.457A
8.401A
8.497A
2.390A
584.707
88.386%
1710
43.8
43.61°C
0.994
12.111V
5.062V
3.307V
5.019V
661.535
50.92°C
115.22V
10
46.476A
8.912A
9.003A
2.495A
649.523
87.458%
1850
45.0
45.10°C
0.994
12.099V
5.052V
3.298V
5.008V
742.667
53.38°C
115.14V
11
51.902A
8.924A
9.020A
2.496A
714.445
86.545%
1865
43.9
46.25°C
0.995
12.085V
5.045V
3.293V
5.002V
825.514
55.18°C
115.15V
CL1
0.100A
12.012A
12.004A
0.004A
102.427
84.444%
1215
33.2
42.99°C
0.955
12.195V
5.083V
3.343V
5.106V
121.296
49.48°C
115.16V
CL2
54.123A
1.004A
1.002A
1.002A
668.198
87.953%
1750
41.6
44.77°C
0.994
12.096V
5.109V
3.324V
5.055V
759.720
52.35°C
115.15V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.539A
1.933A
1.952A
0.976A
64.760
88.096%
930
25.1
40.09°C
0.740
12.210V
5.161V
3.376V
5.105V
73.511
42.68°C
230.24V
2
8.108A
2.918A
2.934A
1.176A
129.851
91.890%
930
25.1
40.44°C
0.874
12.203V
5.151V
3.370V
5.095V
141.311
43.55°C
230.24V
3
13.022A
3.404A
3.443A
1.376A
194.911
92.863%
930
25.1
41.14°C
0.925
12.196V
5.144V
3.365V
5.087V
209.890
44.50°C
230.25V
4
17.935A
3.890A
3.926A
1.575A
259.780
93.251%
930
25.1
41.75°C
0.943
12.189V
5.137V
3.360V
5.077V
278.580
45.44°C
230.25V
5
22.520A
4.876A
4.918A
1.776A
324.784
93.137%
960
26.5
42.10°C
0.954
12.180V
5.127V
3.353V
5.068V
348.715
46.58°C
230.25V
6
27.107A
5.859A
5.916A
1.976A
389.745
92.824%
1155
31.7
42.71°C
0.962
12.173V
5.118V
3.345V
5.059V
419.873
47.94°C
230.25V
7
31.692A
6.855A
6.915A
2.176A
454.635
92.427%
1380
37.7
43.11°C
0.968
12.166V
5.105V
3.339V
5.049V
491.883
48.66°C
230.26V
8
36.298A
7.855A
7.918A
2.380A
519.682
91.995%
1495
38.9
43.58°C
0.970
12.157V
5.095V
3.333V
5.040V
564.904
49.40°C
230.26V
9
41.326A
8.357A
8.446A
2.380A
584.700
91.608%
40.9
1630
44.10°C
0.975
12.150V
5.087V
3.326V
5.036V
638.262
50.37°C
230.26V
10
46.317A
8.860A
8.942A
2.484A
649.571
91.134%
44.7
1775
45.27°C
0.977
12.142V
5.080V
3.320V
5.030V
712.767
51.98°C
230.26V
11
51.692A
8.868A
8.954A
2.485A
714.451
90.633%
1865
43.9
46.47°C
0.981
12.135V
5.074V
3.315V
5.026V
788.289
53.64°C
230.26V
CL1
0.100A
12.012A
12.006A
0.005A
102.884
86.554%
990
27.4
42.93°C
0.846
12.204V
5.105V
3.358V
5.117V
118.867
48.27°C
230.25V
CL2
53.974A
1.002A
1.001A
1.002A
668.911
91.829%
1675
42.8
45.30°C
0.978
12.142V
5.126V
3.337V
5.071V
728.428
51.61°C
230.26V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
PF/AC Volts
1
1.196A
0.480A
0.472A
0.195A
19.685
76.118%
930
25.1
0.779
12.212V
5.173V
3.383V
5.127V
25.861
115.16V
2
2.416A
0.959A
0.974A
0.391A
39.748
84.192%
930
25.1
0.892
12.209V
5.168V
3.379V
5.121V
47.211
115.16V
3
3.642A
1.454A
1.480A
0.586A
59.949
87.126%
930
25.1
0.941
12.205V
5.163V
3.375V
5.113V
68.807
115.16V
4
4.853A
1.933A
1.957A
0.780A
79.769
88.352%
930
25.1
0.937
12.202V
5.158V
3.373V
5.106V
90.285
115.16V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.196A
0.480A
0.473A
0.196A
19.696
76.397%
930
25.1
0.507
12.215V
5.173V
3.383V
5.127V
25.781
230.25V
2
2.416A
0.959A
0.977A
0.391A
39.768
84.958%
930
25.1
0.637
12.213V
5.169V
3.380V
5.122V
46.809
230.25V
3
3.638A
1.455A
1.480A
0.586A
59.937
88.156%
930
25.1
0.720
12.211V
5.165V
3.379V
5.115V
67.990
230.26V
4
4.854A
1.932A
1.955A
0.780A
79.780
89.677%
930
25.1
0.783
12.203V
5.158V
3.373V
5.112V
88.964
230.25V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
8.1 mV
9.6 mV
8.6 mV
7.3 mV
Pass
20% Load
12.4 mV
10.1 mV
10.4 mV
7.9 mV
Pass
30% Load
15.9 mV
9.9 mV
10.8 mV
8.4 mV
Pass
40% Load
18.0 mV
12.1 mV
12.1 mV
9.4 mV
Pass
50% Load
21.0 mV
12.1 mV
14.6 mV
9.8 mV
Pass
60% Load
24.5 mV
12.2 mV
16.1 mV
10.9 mV
Pass
70% Load
29.8 mV
13.0 mV
19.9 mV
11.4 mV
Pass
80% Load
33.7 mV
14.9 mV
20.8 mV
12.2 mV
Pass
90% Load
36.1 mV
15.5 mV
22.6 mV
13.6 mV
Pass
100% Load
41.9 mV
18.9 mV
28.2 mV
15.7 mV
Pass
110% Load
49.6 mV
19.1 mV
31.6 mV
15.7 mV
Pass
Crossload 1
22.8 mV
17.3 mV
24.2 mV
20.2 mV
Pass
Crossload 2
35.9 mV
15.8 mV
18.1 mV
13.4 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
9.7 mV
9.5 mV
10.3 mV
7.8 mV
Pass
20% Load
13.9 mV
10.0 mV
11.3 mV
8.5 mV
Pass
30% Load
17.8 mV
10.7 mV
12.2 mV
8.8 mV
Pass
40% Load
20.4 mV
12.5 mV
13.9 mV
10.0 mV
Pass
50% Load
24.2 mV
12.6 mV
16.4 mV
11.1 mV
Pass
60% Load
28.4 mV
12.5 mV
19.8 mV
11.5 mV
Pass
70% Load
32.8 mV
12.8 mV
21.1 mV
12.6 mV
Pass
80% Load
35.8 mV
13.2 mV
23.3 mV
12.9 mV
Pass
90% Load
40.0 mV
14.0 mV
25.9 mV
13.9 mV
Pass
100% Load
45.1 mV
18.0 mV
29.5 mV
15.7 mV
Pass
110% Load
52.4 mV
18.4 mV
32.2 mV
16.1 mV
Pass
Crossload 1
26.4 mV
14.0 mV
26.6 mV
19.8 mV
Pass
Crossload 2
36.0 mV
13.9 mV
18.8 mV
12.4 mV
Pass
The results above are not used in the certification process