ErP Lot 6 2010: ✓
ErP Lot 6 2013: ✓
ErP Lot 3 2014: Partially
(EU) No 617/2013 Compliance
✓
Performance Summary
Efficiency Rating
SILVER
Noise Rating
Standard++
Average Efficiency (>1450 load combinations)
91.349%
Average Noise Output (>1450 Load Combinations)
32.87dBA
Average PF (>1450 Load Combinations)
0.968
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.0871W
12V Ripple (Full Load)
34.70mV
5V Ripple (Full Load)
28.93mV
3.3V Ripple (Full Load)
41.25mV
5VSB Ripple (Full Load)
22.79mV
12V Load Regulation
1.58%
5V Load Regulation
1.72%
3.3V Load Regulation
2.57%
5VSB Load Regulation
3.53%
Inrush Current
100.662A
Efficiency Rating
Noise Rating
Average Efficiency (>1450 load combinations)
92.860%
Average Noise Output (>1450 Load Combinations)
0.00dBA
Average PF (>1450 Load Combinations)
0.000
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.1115W
12V Ripple (Full Load)
41.12mV
5V Ripple (Full Load)
23.04mV
3.3V Ripple (Full Load)
28.61mV
5VSB Ripple (Full Load)
20.71mV
12V Load Regulation
1.38%
5V Load Regulation
0.87%
3.3V Load Regulation
2.72%
5VSB Load Regulation
2.83%
Inrush Current
56.556A
12V Transient Response (150%)
0.00V
5V Transient Response (150%)
V
3.3V Transient Response (150%)
V
5VSB Transient Response (150%)
V
Hold-Up Time & Power Ok Signal
8.60ms
AC Loss to PWR_OK Hold Up Time
31.80ms
PWR_OK Inactive to DC Loss Delay
-23.20ms
PSU Timings: T1 (20% / 100%)
0.0ms
0.0ms
PSU Timings: T3 (20% / 100%)
0.0ms
0.0ms
OPP (0.00°C / 0.00°C)
0.00%
0.00%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
8.6
AC Loss to PWR_OK Hold Up Time (ms)
31.8
PWR_OK Inactive to DC Loss Delay (ms)
-23.2
Vampire Power
Tables
Graphs
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.211
60.807%
0.065
5.053V
0.347
115.18V
2
0.087A
0.441
68.692%
0.112
5.050V
0.642
115.18V
3
0.542A
2.725
77.857%
0.284
5.025V
3.500
115.18V
4
1.002A
5.010
78.798%
0.324
4.999V
6.358
115.18V
5
1.502A
7.466
79.114%
0.346
4.971V
9.437
115.18V
6
3.002A
14.716
77.436%
0.385
4.902V
19.004
115.18V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.211
55.236%
0.021
5.053V
0.382
230.42V
2
0.087A
0.441
63.453%
0.038
5.049V
0.695
230.42V
3
0.542A
2.723
74.849%
0.164
5.021V
3.638
230.42V
4
1.002A
5.008
77.201%
0.230
4.997V
6.487
230.42V
5
1.502A
7.462
77.948%
0.270
4.969V
9.573
230.42V
6
3.002A
14.681
78.638%
0.325
4.891V
18.669
230.41V
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
4.836A
1.983A
1.975A
0.996A
79.782
90.709%
1415
36.9
38.23°C
0.933
12.034V
5.045V
3.338V
5.009V
87.954
40.19°C
115.17V
2
10.721A
2.969A
2.969A
1.201A
159.629
93.212%
1460
37.0
38.42°C
0.953
12.013V
5.036V
3.330V
4.995V
171.254
40.69°C
115.16V
3
16.991A
3.485A
3.489A
1.405A
239.879
93.503%
1460
37.0
38.98°C
0.964
11.993V
5.028V
3.321V
4.980V
256.547
41.73°C
115.15V
4
23.264A
3.986A
3.981A
1.611A
319.739
93.283%
1460
37.0
39.43°C
0.968
11.973V
5.020V
3.313V
4.966V
342.764
42.92°C
115.15V
5
29.211A
4.985A
4.992A
1.816A
399.616
92.434%
1460
37.0
39.97°C
0.973
11.953V
5.010V
3.304V
4.950V
432.324
44.41°C
115.14V
6
35.184A
5.999A
6.008A
2.025A
479.609
91.880%
1460
37.0
40.74°C
0.978
11.932V
5.002V
3.294V
4.937V
521.996
46.17°C
115.14V
7
41.183A
7.013A
7.031A
2.232A
559.567
91.223%
1460
37.0
41.63°C
0.980
11.910V
4.990V
3.285V
4.922V
613.406
48.33°C
115.13V
8
47.202A
8.030A
8.059A
2.444A
639.537
90.486%
1460
37.0
43.33°C
0.983
11.888V
4.983V
3.275V
4.907V
706.782
51.49°C
115.13V
9
53.681A
8.546A
8.598A
2.446A
719.566
89.766%
1470
37.1
44.09°C
0.986
11.866V
4.973V
3.268V
4.902V
801.607
54.21°C
115.13V
10
59.918A
9.068A
9.112A
3.080A
799.429
89.036%
1470
37.1
44.96°C
0.988
11.845V
4.965V
3.258V
4.867V
897.876
56.28°C
115.13V
11
66.781A
9.076A
9.131A
3.086A
879.281
88.176%
1470
37.1
45.99°C
0.988
11.824V
4.957V
3.250V
4.860V
997.188
59.32°C
115.12V
CL1
0.098A
12.012A
12.004A
0.004A
101.363
87.823%
1460
37.0
44.19°C
0.940
12.011V
5.027V
3.314V
5.083V
115.418
52.34°C
115.17V
CL2
64.937A
1.003A
1.004A
1.002A
783.725
89.802%
1470
37.1
44.43°C
0.988
11.865V
4.983V
3.281V
4.946V
872.723
55.67°C
115.13V
The results above are not used in the certification process
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
PF/AC Volts
1
1.212A
0.493A
0.476A
0.196A
19.667
78.351%
1260
34.4
0.850
12.041V
5.053V
3.347V
5.045V
25.101
115.18V
2
2.453A
0.984A
0.984A
0.396A
39.779
86.051%
1335
35.0
0.906
12.035V
5.052V
3.344V
5.036V
46.227
115.17V
3
3.694A
1.478A
1.493A
0.596A
59.884
88.729%
1395
36.6
0.904
12.030V
5.048V
3.341V
5.028V
67.491
115.17V
4
4.920A
1.985A
1.974A
0.796A
79.807
90.756%
1415
36.9
0.932
12.034V
5.046V
3.338V
5.018V
87.936
115.17V
The results above are not used in the certification process
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
26.3 mV
11.2 mV
13.4 mV
8.1 mV
Pass
20% Load
19.4 mV
12.7 mV
14.5 mV
9.7 mV
Pass
30% Load
19.6 mV
15.8 mV
16.8 mV
11.9 mV
Pass
40% Load
20.3 mV
15.2 mV
18.0 mV
12.4 mV
Pass
50% Load
20.9 mV
16.6 mV
19.7 mV
14.1 mV
Pass
60% Load
22.2 mV
21.2 mV
21.2 mV
16.8 mV
Pass
70% Load
25.1 mV
20.7 mV
25.7 mV
17.2 mV
Pass
80% Load
27.4 mV
21.5 mV
29.7 mV
17.9 mV
Pass
90% Load
29.1 mV
25.6 mV
32.2 mV
20.2 mV
Pass
100% Load
34.7 mV
28.9 mV
41.3 mV
22.8 mV
Pass
110% Load
36.4 mV
30.2 mV
38.7 mV
23.7 mV
Pass
Crossload 1
27.9 mV
19.2 mV
24.9 mV
12.4 mV
Pass
Crossload 2
31.0 mV
21.7 mV
30.2 mV
20.1 mV
Pass
The results above are not used in the certification process
The results above are not used in the certification process
SAMA Forza Titanium 800W
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted