This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
115V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
115V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC) 115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.208
70.270%
0.031
5.008V
0.296
115.12V
2
0.087A
0.435
76.049%
0.059
5.006V
0.572
115.13V
3
0.532A
2.658
79.629%
0.259
4.998V
3.338
115.09V
4
1.002A
4.999
79.475%
0.350
4.989V
6.290
115.09V
5
1.502A
7.476
79.245%
0.395
4.979V
9.434
115.10V
6
3.001A
14.853
78.215%
0.454
4.949V
18.990
115.11V
Supplementary Tests (For Reference)
Typical Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
2.726A
1.975A
2.013A
1.002A
54.763
79.027%
930
19.3
38.66°C
0.971
12.180V
5.054V
3.275V
4.976V
69.297
44.02°C
115.12V
2
6.483A
2.967A
3.024A
1.207A
109.780
85.439%
930
19.3
38.85°C
0.989
12.172V
5.050V
3.271V
4.965V
128.489
44.88°C
115.12V
3
10.590A
3.467A
3.545A
1.411A
164.886
87.240%
930
19.3
39.20°C
0.994
12.163V
5.048V
3.270V
4.951V
189.003
46.25°C
115.14V
4
14.696A
3.964A
4.036A
1.616A
219.779
87.877%
930
19.3
39.66°C
0.996
12.154V
5.044V
3.267V
4.940V
250.098
47.81°C
115.13V
5
18.470A
4.963A
5.053A
1.826A
274.810
87.746%
1000
20.1
40.36°C
0.997
12.144V
5.042V
3.263V
4.928V
313.188
50.05°C
115.13V
6
22.248A
5.955A
6.069A
2.033A
329.752
87.212%
1290
27.0
41.02°C
0.997
12.135V
5.038V
3.260V
4.912V
378.106
50.98°C
115.14V
7
26.033A
6.957A
7.091A
2.245A
384.757
86.514%
1570
31.8
41.91°C
0.996
12.125V
5.034V
3.256V
4.898V
444.734
52.19°C
115.14V
8
29.823A
7.952A
8.113A
2.455A
439.667
85.730%
1830
36.8
42.75°C
0.997
12.114V
5.031V
3.253V
4.885V
512.852
53.39°C
115.13V
9
34.046A
8.461A
8.643A
2.459A
494.766
84.919%
2055
39.8
43.69°C
0.997
12.105V
5.029V
3.251V
4.876V
582.634
54.86°C
115.13V
10
38.024A
8.959A
9.139A
3.086A
549.632
83.997%
2165
41.5
44.96°C
0.997
12.096V
5.025V
3.249V
4.855V
654.346
57.14°C
115.13V
11
42.603A
8.961A
9.145A
3.091A
604.586
83.008%
2165
41.5
45.80°C
0.997
12.086V
5.023V
3.247V
4.847V
728.351
59.00°C
115.13V
CL1
0.098A
14.025A
14.004A
0.004A
117.495
81.539%
930
19.3
42.68°C
0.990
12.162V
5.038V
3.258V
4.965V
144.097
52.23°C
115.13V
CL2
45.787A
1.004A
1.002A
1.000A
567.264
84.347%
2165
41.5
44.33°C
0.997
12.100V
5.039V
3.263V
4.912V
672.537
56.24°C
115.13V
The results above are not used in the certification process
Light Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
PF/AC Volts
1
1.200A
0.491A
0.486A
0.201A
19.708
63.890%
930
19.3
0.916
12.188V
5.058V
3.279V
4.998V
30.847
115.12V
2
2.422A
0.980A
1.005A
0.401A
39.760
75.859%
885
19.0
0.958
12.184V
5.057V
3.278V
4.991V
52.413
115.12V
3
3.648A
1.477A
1.526A
0.601A
59.890
80.894%
930
19.3
0.973
12.180V
5.056V
3.276V
4.985V
74.035
115.12V
4
4.862A
1.975A
2.015A
0.801A
79.772
83.381%
950
19.5
0.983
12.177V
5.054V
3.275V
4.977V
95.672
115.12V
The results above are not used in the certification process
Ripple Measurements 115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
7.5 mV
8.9 mV
9.6 mV
11.2 mV
Pass
20% Load
7.7 mV
8.1 mV
9.4 mV
11.4 mV
Pass
30% Load
10.4 mV
9.4 mV
10.2 mV
12.5 mV
Pass
40% Load
10.4 mV
9.3 mV
10.3 mV
13.7 mV
Pass
50% Load
14.1 mV
10.2 mV
11.0 mV
14.7 mV
Pass
60% Load
17.1 mV
10.0 mV
11.3 mV
17.8 mV
Pass
70% Load
19.6 mV
10.5 mV
12.4 mV
20.3 mV
Pass
80% Load
22.9 mV
11.7 mV
12.3 mV
22.3 mV
Pass
90% Load
24.6 mV
12.1 mV
14.6 mV
23.6 mV
Pass
100% Load
27.2 mV
15.0 mV
14.6 mV
25.7 mV
Pass
110% Load
28.7 mV
14.7 mV
15.6 mV
27.2 mV
Pass
Crossload 1
9.7 mV
10.6 mV
11.2 mV
13.5 mV
Pass
Crossload 2
27.9 mV
15.2 mV
15.3 mV
24.8 mV
Pass