This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.212
61.628%
0.064
5.090V
0.344
115.11V
2
0.087A
0.443
72.150%
0.111
5.089V
0.614
115.11V
3
0.532A
2.702
79.752%
0.324
5.080V
3.388
115.10V
4
1.002A
5.080
80.956%
0.378
5.069V
6.275
115.10V
5
1.502A
7.597
80.862%
0.406
5.059V
9.395
115.10V
6
3.001A
15.084
79.111%
0.449
5.026V
19.067
115.10V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.212
49.882%
0.024
5.090V
0.425
230.30V
2
0.087A
0.443
64.017%
0.039
5.089V
0.692
230.29V
3
0.532A
2.701
78.403%
0.167
5.080V
3.445
230.28V
4
1.002A
5.080
79.091%
0.247
5.069V
6.423
230.28V
5
1.502A
7.596
79.506%
0.295
5.058V
9.554
230.28V
6
3.002A
15.083
79.678%
0.358
5.025V
18.930
230.28V
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.145A
1.980A
1.958A
0.985A
59.772
83.428%
568
17.4
38.23°C
0.964
12.147V
5.050V
3.364V
5.061V
71.645
41.57°C
115.11V
2
7.327A
2.970A
2.946A
1.187A
119.772
88.196%
568
17.4
38.72°C
0.980
12.136V
5.042V
3.355V
5.049V
135.802
42.21°C
115.11V
3
11.861A
3.481A
3.462A
1.385A
179.884
89.548%
568
17.4
39.17°C
0.987
12.126V
5.029V
3.344V
5.036V
200.881
43.08°C
115.10V
4
16.392A
3.982A
3.949A
1.591A
239.782
89.733%
568
17.4
39.37°C
0.992
12.117V
5.021V
3.336V
5.024V
267.216
44.21°C
115.10V
5
20.587A
4.985A
4.952A
1.796A
299.681
89.357%
568
17.4
40.19°C
0.995
12.107V
5.010V
3.325V
5.008V
335.376
45.76°C
115.10V
6
24.800A
5.997A
5.960A
2.001A
359.724
88.708%
568
17.4
41.16°C
0.997
12.096V
5.000V
3.316V
4.995V
405.514
47.89°C
115.11V
7
29.016A
7.014A
6.979A
2.204A
419.656
87.840%
910
19.7
41.90°C
0.998
12.084V
4.988V
3.304V
4.983V
477.750
48.92°C
115.11V
8
33.234A
8.042A
8.003A
2.414A
479.596
87.025%
1165
22.3
42.98°C
0.998
12.074V
4.973V
3.291V
4.970V
551.101
49.98°C
115.10V
9
37.898A
8.554A
8.544A
2.415A
539.660
85.991%
1380
26.6
43.63°C
0.998
12.063V
4.965V
3.282V
4.963V
627.575
51.01°C
115.10V
10
42.307A
9.079A
9.056A
3.030A
599.494
84.694%
1600
31.6
44.44°C
0.998
12.053V
4.954V
3.270V
4.943V
707.836
52.52°C
115.12V
11
47.325A
9.089A
9.074A
3.034A
659.457
83.289%
1685
32.6
45.55°C
0.998
12.042V
4.948V
3.263V
4.940V
791.770
54.49°C
115.12V
CL1
0.101A
17.022A
17.004A
0.004A
142.348
79.857%
935
19.7
43.27°C
0.985
12.115V
4.985V
3.308V
5.040V
178.253
49.27°C
115.10V
CL2
48.307A
1.003A
1.003A
1.002A
596.137
84.638%
1535
30.0
44.45°C
0.998
12.065V
4.979V
3.295V
5.005V
704.340
51.71°C
115.11V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
3.152A
1.984A
1.970A
0.987A
59.939
81.062%
590
17.4
40.30°C
0.839
12.166V
5.038V
3.348V
5.067V
73.942
45.16°C
230.89V
2
7.303A
2.979A
2.960A
1.187A
119.665
87.581%
590
17.4
40.75°C
0.928
12.156V
5.033V
3.342V
5.057V
136.633
46.36°C
230.85V
3
11.817A
3.486A
3.449A
1.388A
179.534
89.771%
590
17.4
41.32°C
0.955
12.147V
5.020V
3.332V
5.044V
199.990
47.35°C
230.81V
4
16.345A
3.997A
3.973A
1.589A
239.570
90.485%
590
17.4
41.86°C
0.970
12.137V
5.003V
3.321V
5.034V
264.761
48.57°C
230.77V
5
20.546A
5.005A
4.974A
1.793A
299.652
90.701%
568
17.4
42.03°C
0.977
12.127V
4.995V
3.315V
5.020V
330.374
49.08°C
230.56V
6
24.751A
6.005A
5.986A
1.998A
359.742
90.458%
685
17.6
42.82°C
0.983
12.119V
4.994V
3.307V
5.005V
397.691
50.54°C
230.69V
7
28.934A
7.019A
7.005A
2.203A
419.461
90.001%
980
19.4
43.15°C
0.987
12.109V
4.987V
3.297V
4.993V
466.063
51.39°C
230.64V
8
33.188A
8.036A
8.034A
2.410A
479.971
89.440%
1265
23.3
43.72°C
0.988
12.100V
4.977V
3.286V
4.980V
536.639
52.44°C
230.60V
9
37.775A
8.550A
8.536A
2.413A
539.231
88.900%
1340
25.6
44.64°C
0.990
12.091V
4.971V
3.279V
4.974V
606.556
53.88°C
230.66V
10
42.213A
9.071A
9.086A
3.027A
599.671
87.942%
1632
32.3
45.79°C
0.991
12.081V
4.961V
3.268V
4.956V
681.897
55.43°C
230.61V
11
47.220A
9.084A
9.104A
3.030A
659.694
87.160%
1685
32.6
46.36°C
0.992
12.071V
4.955V
3.261V
4.951V
756.874
56.75°C
230.56V
CL1
0.128A
17.001A
16.999A
0.000A
142.553
81.193%
717
17.6
43.25°C
0.949
12.136V
4.992V
3.302V
5.050V
175.572
51.47°C
230.81V
CL2
48.000A
1.000A
1.001A
1.000A
593.846
87.821%
1643
32.4
45.72°C
0.991
12.095V
4.982V
3.289V
5.012V
676.199
55.58°C
230.60V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
PF/AC Volts
1
1.198A
0.491A
0.472A
0.196A
19.632
68.089%
568
17.4
0.580
12.155V
5.057V
3.368V
5.083V
28.833
115.14V
2
2.428A
0.981A
0.978A
0.390A
39.731
79.481%
568
17.4
0.745
12.152V
5.053V
3.364V
5.076V
49.988
115.14V
3
3.659A
1.477A
1.484A
0.590A
59.887
84.020%
568
17.4
0.964
12.148V
5.050V
3.362V
5.069V
71.277
115.14V
4
4.876A
1.978A
1.959A
0.787A
79.765
86.006%
568
17.4
0.969
12.141V
5.051V
3.363V
5.064V
92.743
115.12V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.180A
0.495A
0.475A
0.197A
19.459
62.946%
590
17.4
0.470
12.174V
5.045V
3.355V
5.088V
30.914
230.97V
2
2.429A
0.990A
0.983A
0.394A
39.850
76.359%
590
17.4
0.647
12.171V
5.041V
3.351V
5.080V
52.188
230.90V
3
3.614A
1.487A
1.461A
0.591A
59.358
81.572%
590
17.4
0.836
12.168V
5.039V
3.348V
5.073V
72.768
230.89V
4
4.858A
1.977A
1.965A
0.789A
79.687
84.162%
590
17.4
0.884
12.167V
5.053V
3.353V
5.071V
94.683
230.76V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
6.4 mV
13.9 mV
11.0 mV
11.8 mV
Pass
20% Load
10.6 mV
17.3 mV
15.3 mV
13.4 mV
Pass
30% Load
10.5 mV
19.4 mV
17.8 mV
15.4 mV
Pass
40% Load
11.5 mV
20.1 mV
20.5 mV
16.4 mV
Pass
50% Load
13.2 mV
21.6 mV
22.2 mV
17.3 mV
Pass
60% Load
15.9 mV
22.9 mV
24.7 mV
19.0 mV
Pass
70% Load
19.5 mV
24.2 mV
27.2 mV
20.2 mV
Pass
80% Load
23.0 mV
25.4 mV
29.9 mV
21.6 mV
Pass
90% Load
28.5 mV
28.7 mV
32.6 mV
22.9 mV
Pass
100% Load
35.1 mV
29.7 mV
35.4 mV
26.0 mV
Pass
110% Load
46.9 mV
31.6 mV
38.8 mV
27.9 mV
Pass
Crossload 1
18.3 mV
24.5 mV
18.7 mV
20.2 mV
Pass
Crossload 2
31.3 mV
31.2 mV
37.8 mV
24.4 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
6.9 mV
12.5 mV
9.3 mV
18.5 mV
Pass
20% Load
8.6 mV
14.5 mV
11.8 mV
20.5 mV
Pass
30% Load
9.2 mV
16.8 mV
14.4 mV
21.5 mV
Pass
40% Load
11.0 mV
18.3 mV
17.1 mV
22.7 mV
Pass
50% Load
11.7 mV
20.0 mV
18.9 mV
13.9 mV
Pass
60% Load
12.7 mV
25.4 mV
21.9 mV
14.7 mV
Pass
70% Load
14.9 mV
28.1 mV
24.0 mV
18.3 mV
Pass
80% Load
20.0 mV
28.1 mV
27.7 mV
19.5 mV
Pass
90% Load
22.0 mV
28.2 mV
30.1 mV
19.5 mV
Pass
100% Load
23.3 mV
32.3 mV
34.5 mV
18.3 mV
Pass
110% Load
26.4 mV
32.7 mV
38.1 mV
19.7 mV
Pass
Crossload 1
10.0 mV
25.9 mV
21.7 mV
22.7 mV
Pass
Crossload 2
24.4 mV
30.1 mV
31.1 mV
21.7 mV
Pass
The results above are not used in the certification process
Be quiet! Pure Power 10 600W
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted