This product certification body is accredited in accordance with the recognized International Standard ISO/IEC 17065:2012 Requirements for bodies certifying products, processes and services. This product certification body also meets the A2LA R308 - Specific Requirements - ISO-IEC 17065 - Telecommunication Certification Body Accreditation Program and R322 - Specific Requirements - Notified Body Accreditation Requirements. This accreditation demonstrates technical competence for a defined scope and the operation of a management system
Aristeidis Bitziopoulos, Laboratory General Manager
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
115V
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
115V
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.216
63.529%
0.055
5.157V
0.340
115.11V
2
0.087A
0.451
70.249%
0.100
5.154V
0.642
115.10V
3
0.532A
2.729
80.668%
0.295
5.128V
3.383
115.09V
4
1.002A
5.113
80.003%
0.352
5.101V
6.391
115.09V
5
1.502A
7.619
79.373%
0.383
5.073V
9.599
115.09V
6
3.001A
14.952
76.258%
0.432
4.982V
19.607
115.09V
Supplementary Tests (For Reference)
115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
5.158A
1.975A
1.978A
0.981A
84.802
81.804%
1420
36.0
38.56°C
0.960
12.256V
5.070V
3.329V
5.085V
103.665
42.45°C
115.11V
2
11.351A
2.959A
2.985A
1.184A
169.658
86.219%
1475
37.5
39.03°C
0.983
12.228V
5.060V
3.314V
5.062V
196.776
45.08°C
115.10V
3
17.928A
3.467A
3.514A
1.385A
254.888
87.372%
1600
38.7
39.81°C
0.983
12.205V
5.049V
3.299V
5.039V
291.727
45.98°C
115.09V
4
24.505A
3.972A
4.014A
1.593A
339.776
87.476%
1660
40.3
40.69°C
0.986
12.185V
5.037V
3.285V
5.015V
388.420
47.14°C
115.09V
5
30.775A
4.973A
5.045A
1.801A
424.671
87.124%
1680
40.9
41.18°C
0.988
12.159V
5.026V
3.270V
4.990V
487.433
48.87°C
115.08V
6
37.075A
5.983A
6.085A
2.011A
509.653
86.493%
1760
42.8
42.08°C
0.989
12.134V
5.015V
3.253V
4.965V
589.240
51.30°C
115.08V
7
43.390A
7.001A
7.138A
2.225A
594.616
85.639%
1795
43.6
42.89°C
0.990
12.111V
5.004V
3.236V
4.938V
694.327
53.91°C
115.07V
8
49.746A
8.018A
8.201A
2.441A
679.518
84.639%
1815
43.7
43.67°C
0.991
12.084V
4.990V
3.218V
4.910V
802.840
55.06°C
115.07V
9
56.554A
8.539A
8.767A
2.446A
764.573
83.728%
1825
43.8
44.63°C
0.992
12.059V
4.978V
3.205V
4.899V
913.167
57.46°C
115.07V
10
63.129A
9.067A
9.313A
3.093A
849.331
82.421%
1825
43.8
45.08°C
0.992
12.033V
4.965V
3.189V
4.844V
1030.480
58.38°C
115.06V
11
70.325A
9.088A
9.355A
3.103A
934.359
81.131%
1825
43.8
46.45°C
0.992
12.011V
4.951V
3.175V
4.830V
1151.665
60.29°C
115.05V
CL1
0.100A
17.022A
17.003A
0.005A
143.268
79.120%
1740
42.0
44.76°C
0.986
12.204V
5.087V
3.260V
5.106V
181.077
48.96°C
115.11V
CL2
70.793A
1.003A
1.003A
1.002A
865.765
82.652%
1825
43.8
46.28°C
0.993
12.043V
4.954V
3.224V
4.993V
1047.486
59.98°C
115.06V
The results above are not used in the certification process
115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
PF/AC Volts
1
1.190A
0.491A
0.477A
0.191A
19.683
61.886%
1295
33.8
0.705
12.279V
5.079V
3.344V
5.142V
31.805
115.11V
2
2.406A
0.980A
0.987A
0.391A
39.800
73.283%
1300
33.9
0.867
12.271V
5.076V
3.340V
5.127V
54.310
115.11V
3
3.620A
1.468A
1.496A
0.586A
59.857
79.726%
1390
35.2
0.922
12.271V
5.073V
3.335V
5.112V
75.078
115.11V
4
4.832A
1.974A
1.979A
0.782A
79.811
81.458%
1400
35.4
0.955
12.257V
5.071V
3.330V
5.097V
97.978
115.13V
The results above are not used in the certification process
115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
9.1 mV
7.6 mV
11.9 mV
5.8 mV
Pass
20% Load
10.5 mV
8.0 mV
14.7 mV
7.1 mV
Pass
30% Load
10.7 mV
8.4 mV
15.2 mV
8.3 mV
Pass
40% Load
12.0 mV
8.4 mV
15.9 mV
9.1 mV
Pass
50% Load
14.1 mV
8.5 mV
14.9 mV
8.4 mV
Pass
60% Load
15.0 mV
8.5 mV
15.3 mV
9.0 mV
Pass
70% Load
17.4 mV
8.7 mV
14.4 mV
10.5 mV
Pass
80% Load
18.8 mV
10.1 mV
15.9 mV
11.4 mV
Pass
90% Load
20.7 mV
10.0 mV
16.3 mV
12.6 mV
Pass
100% Load
25.7 mV
11.8 mV
17.5 mV
19.2 mV
Pass
110% Load
32.5 mV
12.1 mV
17.5 mV
20.8 mV
Pass
Crossload 1
11.9 mV
9.1 mV
15.9 mV
6.8 mV
Pass
Crossload 2
24.6 mV
11.0 mV
18.9 mV
11.6 mV
Pass
The results above are not used in the certification process