C-Link USB Cable (800mm) / C-Link I2C Cable (800mm)
1 / 1
1 / 1
24-28 / 29AWG
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary 115V
Efficiency Rating
PLATINUM
Noise Rating
A+
Average Efficiency (>1450 load combinations)
89.819%
Average Noise Output (>1450 Load Combinations)
19.10dBA
Average PF (>1450 Load Combinations)
0.992
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.0407W
12V Ripple (Full Load)
32.59mV
5V Ripple (Full Load)
9.22mV
3.3V Ripple (Full Load)
14.35mV
5VSB Ripple (Full Load)
13.00mV
12V Load Regulation
1.14%
5V Load Regulation
1.17%
3.3V Load Regulation
0.60%
5VSB Load Regulation
1.90%
Inrush Current
27.922A
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
21.72
AC Loss to PWR_OK Hold Up Time (ms)
17.00
PWR_OK Inactive to DC Loss Delay (ms)
4.72
Vampire Power
Tables 115V
Graphs 115V
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
115V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
115V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC) 115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.213
70.530%
0.030
5.067V
0.302
115.07V
2
0.088A
0.444
76.552%
0.058
5.066V
0.580
115.07V
3
0.532A
2.690
80.131%
0.271
5.053V
3.357
115.08V
4
3.002A
14.952
77.745%
0.527
4.981V
19.232
115.07V
Supplementary Tests (For Reference)
Typical Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
4.384A
2.006A
2.000A
1.006A
74.806
86.349%
0
0
45.89°C
0.972
12.131V
4.998V
3.298V
4.972V
86.632
38.07°C
115.12V
2
9.814A
2.990A
2.999A
1.201A
149.769
90.393%
0
0
46.77°C
0.986
12.117V
5.009V
3.299V
4.981V
165.686
38.64°C
115.11V
3
15.598A
3.483A
3.509A
1.399A
224.850
91.770%
0
0
47.56°C
0.992
12.102V
5.027V
3.302V
4.995V
245.014
39.23°C
115.11V
4
21.390A
3.976A
3.986A
1.601A
299.735
92.170%
0
0
48.27°C
0.994
12.088V
5.028V
3.309V
4.992V
325.199
39.78°C
115.11V
5
26.860A
4.981A
4.974A
1.805A
374.710
92.063%
0
0
49.23°C
0.995
12.071V
5.019V
3.316V
4.980V
407.015
40.10°C
115.11V
6
32.327A
5.989A
5.973A
2.011A
449.578
91.765%
619
17.6
41.89°C
0.996
12.058V
5.009V
3.313V
4.968V
489.925
51.46°C
115.11V
7
37.812A
7.010A
6.976A
2.218A
524.607
91.346%
718
18.9
42.10°C
0.996
12.046V
4.999V
3.310V
4.955V
574.310
50.89°C
115.10V
8
43.308A
8.024A
7.983A
2.426A
599.537
90.847%
811
20.3
42.44°C
0.996
12.033V
4.988V
3.307V
4.941V
659.943
51.75°C
115.11V
9
49.256A
8.538A
8.512A
2.431A
674.564
90.315%
917
21.6
43.44°C
0.996
12.018V
4.978V
3.302V
4.935V
746.898
53.20°C
115.10V
10
54.959A
9.065A
9.010A
3.055A
749.405
89.760%
1070
24.8
44.45°C
0.996
12.003V
4.969V
3.296V
4.907V
834.895
54.87°C
115.10V
11
61.283A
9.071A
9.019A
3.058A
824.225
89.102%
1163
27.0
45.76°C
0.996
11.986V
4.963V
3.291V
4.901V
925.037
56.98°C
115.09V
CL1
0.099A
18.028A
18.002A
0.004A
151.215
83.814%
778
19.5
43.76°C
0.989
12.105V
4.968V
3.357V
5.018V
180.418
51.52°C
115.12V
CL2
62.449A
1.005A
1.003A
1.001A
762.683
90.156%
1099
25.7
44.28°C
0.996
12.002V
4.951V
3.251V
4.928V
845.958
54.11°C
115.10V
The results above are not used in the certification process
Light Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
PF/AC Volts
1
1.202A
0.492A
0.481A
0.196A
19.634
68.423%
0
0
0.830
12.147V
5.010V
3.300V
5.002V
28.695
115.16V
2
2.428A
0.990A
1.000A
0.401A
39.737
79.750%
0
0
0.926
12.142V
5.005V
3.299V
4.993V
49.827
115.12V
3
3.659A
1.493A
1.514A
0.601A
59.860
84.010%
0
0
0.944
12.136V
5.000V
3.298V
4.985V
71.253
115.12V
4
4.882A
2.006A
1.999A
0.801A
79.826
87.122%
0
0
0.977
12.131V
4.996V
3.298V
4.977V
91.626
115.12V
The results above are not used in the certification process
Ripple Measurements 115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
7.6 mV
4.7 mV
4.4 mV
4.2 mV
Pass
20% Load
9.8 mV
4.9 mV
5.1 mV
4.8 mV
Pass
30% Load
14.2 mV
5.2 mV
6.0 mV
5.9 mV
Pass
40% Load
17.8 mV
5.4 mV
7.3 mV
7.4 mV
Pass
50% Load
21.8 mV
5.5 mV
7.7 mV
7.8 mV
Pass
60% Load
25.9 mV
6.2 mV
8.8 mV
9.0 mV
Pass
70% Load
23.5 mV
7.1 mV
9.6 mV
9.6 mV
Pass
80% Load
25.7 mV
8.5 mV
11.0 mV
10.5 mV
Pass
90% Load
28.5 mV
8.3 mV
12.6 mV
11.6 mV
Pass
100% Load
32.6 mV
9.2 mV
14.4 mV
13.0 mV
Pass
110% Load
37.2 mV
9.7 mV
15.5 mV
14.7 mV
Pass
Crossload 1
14.9 mV
8.5 mV
9.5 mV
8.3 mV
Pass
Crossload 2
31.4 mV
7.9 mV
13.3 mV
11.7 mV
Pass
The results above are not used in the certification process
Corsair HX750i
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted