C-Link USB Cable (800mm) / C-Link I2C Cable (800mm)
1 / 1
1 / 1
24-28 / 29AWG
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
30-32 / 86-89.6
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✓
Performance Summary 115V
Efficiency Rating
PLATINUM
Noise Rating
A+
Average Efficiency (>1450 load combinations)
89.830%
Average Noise Output (>1450 Load Combinations)
19.22dBA
Average PF (>1450 Load Combinations)
0.993
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.0428W
12V Ripple (Full Load)
38.70mV
5V Ripple (Full Load)
11.08mV
3.3V Ripple (Full Load)
16.79mV
5VSB Ripple (Full Load)
16.04mV
12V Load Regulation
1.33%
5V Load Regulation
1.18%
3.3V Load Regulation
0.69%
5VSB Load Regulation
2.08%
Inrush Current
28.456A
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
19.54
AC Loss to PWR_OK Hold Up Time (ms)
15.74
PWR_OK Inactive to DC Loss Delay (ms)
3.80
Vampire Power
Tables 115V
Graphs 115V
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
115V
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
115V
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC) 115V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.042A
0.213
70.530%
0.030
5.075V
0.302
115.08V
2
0.088A
0.444
76.420%
0.057
5.074V
0.581
115.07V
3
0.532A
2.693
80.340%
0.269
5.061V
3.352
115.08V
4
3.002A
14.965
78.158%
0.530
4.985V
19.147
115.08V
Supplementary Tests (For Reference)
Typical Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
5.219A
1.984A
1.989A
0.996A
84.787
87.619%
0
0
45.19°C
0.978
12.113V
5.035V
3.313V
5.009V
96.768
38.85°C
115.11V
2
11.474A
2.973A
2.988A
1.196A
169.625
91.023%
0
0
45.83°C
0.988
12.096V
5.034V
3.308V
5.004V
186.355
39.09°C
115.11V
3
18.111A
3.467A
3.506A
1.395A
254.889
92.100%
0
0
46.86°C
0.993
12.081V
5.050V
3.305V
5.014V
276.753
39.79°C
115.11V
4
24.747A
3.945A
3.993A
1.591A
339.718
92.267%
0
0
48.09°C
0.995
12.064V
5.065V
3.303V
5.028V
368.191
40.35°C
115.11V
5
31.060A
4.949A
4.967A
1.791A
424.650
92.075%
0
0
50.49°C
0.996
12.046V
5.057V
3.320V
5.016V
461.198
41.66°C
115.10V
6
37.387A
5.945A
5.951A
1.997A
509.548
91.593%
608
17.5
41.32°C
0.997
12.030V
5.047V
3.326V
5.000V
556.315
45.11°C
115.10V
7
43.730A
6.958A
6.952A
2.205A
594.574
91.054%
744
19.2
41.82°C
0.997
12.016V
5.034V
3.322V
4.986V
652.988
44.68°C
115.10V
8
50.083A
7.965A
7.956A
2.411A
679.439
90.403%
845
20.4
42.21°C
0.997
12.001V
5.023V
3.318V
4.972V
751.567
45.05°C
115.10V
9
56.904A
8.479A
8.479A
2.416A
764.426
89.780%
943
22.2
43.53°C
0.997
11.982V
5.013V
3.314V
4.966V
851.445
46.21°C
115.09V
10
63.482A
9.000A
8.976A
3.036A
849.225
88.981%
1101
25.8
44.55°C
0.996
11.964V
5.005V
3.308V
4.937V
954.393
47.57°C
115.09V
11
70.687A
9.012A
8.996A
3.040A
934.022
88.109%
1198
28.5
46.02°C
0.996
11.944V
4.998V
3.302V
4.931V
1060.079
49.03°C
115.08V
CL1
0.099A
18.028A
18.001A
0.004A
152.219
84.132%
787
19.6
43.99°C
0.988
12.084V
5.006V
3.375V
5.062V
180.929
46.83°C
115.12V
CL2
70.791A
1.003A
1.006A
1.002A
860.126
89.348%
1121
26.5
45.21°C
0.996
11.963V
4.987V
3.262V
4.961V
962.666
47.50°C
115.09V
The results above are not used in the certification process
Light Load Tests 115V
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
Fan Noise (dB[A])
PF/AC Volts
1
1.205A
0.491A
0.480A
0.196A
19.679
68.297%
0
0
0.830
12.132V
5.049V
3.315V
5.042V
28.814
115.12V
2
2.436A
0.990A
0.995A
0.396A
39.824
79.814%
0
0
0.928
12.125V
5.045V
3.315V
5.034V
49.896
115.11V
3
3.667A
1.476A
1.506A
0.596A
59.870
84.231%
0
0
0.954
12.120V
5.040V
3.314V
5.025V
71.078
115.11V
4
4.890A
1.989A
1.989A
0.796A
79.838
87.350%
0
0
0.976
12.115V
5.035V
3.313V
5.015V
91.400
115.11V
The results above are not used in the certification process
Ripple Measurements 115V
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
6.1 mV
4.2 mV
4.8 mV
3.9 mV
Pass
20% Load
9.7 mV
4.2 mV
5.7 mV
4.8 mV
Pass
30% Load
13.5 mV
4.6 mV
6.8 mV
6.0 mV
Pass
40% Load
17.1 mV
4.9 mV
7.4 mV
6.8 mV
Pass
50% Load
21.1 mV
5.1 mV
9.4 mV
7.9 mV
Pass
60% Load
21.9 mV
5.9 mV
9.5 mV
9.1 mV
Pass
70% Load
25.1 mV
6.6 mV
11.4 mV
9.7 mV
Pass
80% Load
28.2 mV
7.1 mV
12.6 mV
11.6 mV
Pass
90% Load
32.6 mV
8.1 mV
14.4 mV
12.6 mV
Pass
100% Load
38.7 mV
11.1 mV
16.8 mV
16.0 mV
Pass
110% Load
47.2 mV
12.4 mV
18.9 mV
17.7 mV
Pass
Crossload 1
13.4 mV
7.1 mV
9.5 mV
7.7 mV
Pass
Crossload 2
37.1 mV
8.0 mV
15.3 mV
12.7 mV
Pass
The results above are not used in the certification process
Corsair HX850i
Top side
Power specifications label
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted