Customer: SeaSonic
Everdenberg 117, NL-4902 TT Oosterhout. Seasonic Electronics,
Inc. 301 Aerojet Ave Azusa, USA 91702 Attn: Jessica Su

X-Series 1250W

Report Number: 19PS337A
Customer ID: 12

Test Report Results

Section A: Testing Equipment

Electronic Loads

Chroma 63601-5 x2
Chroma 63600-2
63640-80-80 x10
63610-80-20

AC Sources Chroma 6530, APM SP300VAC4000W-P
Power Analyzers RS HMC8015
Oscilloscopes Picoscope 4444, Siglent SDS2104X PLUS
Sound Analyzer Bruel & Kjaer 2270 G4
Microphone Bruel & Kjaer Type 4955-A
Temperature Logger Picoscope TC-08
Tachometer UNI-T UT372
Multimeters Keysight 34465A
UPS FSP Champ Tower 3kVA, CyberPower OLS3000E 3kVA
Isolation Transformer 4kVA
Testing Methodology Cybenetics PSU Test Protocol

Section B: ETA

Voltage115V230V
Efficiency (>1450 Load Combinations)89.288%91.727%
Efficiency Graphs
Average PF (>1450 Load Combinations)0.9920.961
Standby Power Consumption0.0891W0.1381W
ErP Lot 3/6 ReadyErP Lot 3/6 2010: ✓
ErP Lot 3/6 2013: ✓
ErP Lot 3/6 2014, CEC: Partially
(EU) No 617/2013 Compliance
Average Efficiency VSB79.199%77.083%

Section C: LAMBDA

Voltage115V230V
Noise Rating (>1450 Load Combinations)42.12dBA42.14dBA
Noise Graphs

Section D: Information about DUT

Model NameSeaSonic
Serial NumberR1404AA134610005
Comments
Date of receiptMar 14, 2018
Testing DateMar 28, 2018
Report Issued DateMar 25, 2018
Engineer Name0
Authorized By the Laboratory General ManagerAristeidis Bitziopoulos

Section E: Deviation Additions, deviations, and exceptions to the method table

Uncertainty

The Noise Measurement’s Uncertainty is ±1.18 dB. The reported expanded uncertainty is based on a standard uncertainty multiplied by a coverage factor k=2, providing a level of confidence of approximately 95%.

The reported noise measurement’s level is the mean of 10 repeated measurements at an environment with a temperature deviation of ±2 degrees Celsius. The uncertainty was estimated according to the method in UKAS Publication M 3003.

Uncertainty Budget
Source of uncertainty Value ± Probability distribution Divisor Standard uncertainty
Calibrator’s calibration 0.2 dB Normal 2 0.1
Calibrator’s accuracy 0.2 dB Rectangular √3 0.058
Mic Frequency Response 2 dB Rectangular √3 0.577
Temperature Variation 0.04 dB Rectangular √3 0.012
Operator’s Accuracy 0.2 dB Rectangular √3 0.058
Standard uncertainty of mean of 10 repeated readings Normal 1 0.031
Combined Standard Uncertainty Assumed normal 0.59 dB
Expanded Uncertainty Assumed normal (k = 2) 1.18 dB

*Here the (±) half-width divided by √3 is used.