Customer: Cooler Master
8F., No. 788-1, Zhongzheng Rd.,Zhonghe Dist., New Taipei City 23586, Taiwan (R.O.C.)
Lodewijkstraat 1b, 5652 AC Eindhoven, Netherlands

GXII 750W (ATX v3.1) (MWE Gold 750 V3)

Report Number: 24PS2512A
Customer ID: 27

Test Report Results

Section A: Testing Equipment

Electronic Loads

Chroma 63601-5 x2
Chroma 63600-2
63640-80-80 x10
63610-80-20

AC Sources Chroma 6530, APM SP300VAC4000W-P
Power Analyzers RS HMC8015
Oscilloscopes Picoscope 4444, Siglent SDS2104X PLUS
Sound Analyzer Bruel & Kjaer 2270 G4
Microphone Bruel & Kjaer Type 4955-A
Temperature Logger Picoscope TC-08
Tachometer UNI-T UT372
Multimeters Keysight 34465A
UPS FSP Champ Tower 3kVA, CyberPower OLS3000E 3kVA
Isolation Transformer 4kVA
Testing Methodology Cybenetics PSU Test Protocol

Section B: ETA

Voltage115V230V
Efficiency (>1450 Load Combinations)89.246%91.616%
Efficiency Graphs
Average PF (>1450 Load Combinations)0.9890.976
Standby Power Consumption0.0921W0.1331W
ErP Lot 3/6 Ready
(EU) No 617/2013 Compliance
Average Efficiency VSB82.087%81.516%

Section C: LAMBDA

Voltage115V230V
Noise Rating (>1450 Load Combinations)24.27dBA24.18dBA
Noise Graphs

Section D: Information about DUT

Model NameCooler Master
Serial NumberPS57513CD240220044BA1GZ
Comments
Date of receiptJun 25, 2024
Testing DateJul 31, 2024
Report Issued DateJul 22, 2024
Engineer Name0
Authorized By the Laboratory General ManagerAristeidis Bitziopoulos

Section E: Deviation Additions, deviations, and exceptions to the method table

Uncertainty

The Noise Measurement’s Uncertainty is ±1.18 dB. The reported expanded uncertainty is based on a standard uncertainty multiplied by a coverage factor k=2, providing a level of confidence of approximately 95%.

The reported noise measurement’s level is the mean of 10 repeated measurements at an environment with a temperature deviation of ±2 degrees Celsius. The uncertainty was estimated according to the method in UKAS Publication M 3003.

Uncertainty Budget
Source of uncertainty Value ± Probability distribution Divisor Standard uncertainty
Calibrator’s calibration 0.2 dB Normal 2 0.1
Calibrator’s accuracy 0.2 dB Rectangular √3 0.058
Mic Frequency Response 2 dB Rectangular √3 0.577
Temperature Variation 0.04 dB Rectangular √3 0.012
Operator’s Accuracy 0.2 dB Rectangular √3 0.058
Standard uncertainty of mean of 10 repeated readings Normal 1 0.031
Combined Standard Uncertainty Assumed normal 0.59 dB
Expanded Uncertainty Assumed normal (k = 2) 1.18 dB

*Here the (±) half-width divided by √3 is used.