Customer: Cooler Master
8F., No. 788-1, Zhongzheng Rd.,Zhonghe Dist., New Taipei City 23586, Taiwan (R.O.C.)
Lodewijkstraat 1b, 5652 AC Eindhoven, Netherlands

Masterwatt Lite 400W

Report Number: 20PS1754A
Customer ID: 27

Test Report Results

Section A: Testing Equipment

Electronic Loads

Chroma 63601-5 x2
Chroma 63600-2
63640-80-80 x10
63610-80-20

AC Sources Chroma 6530, APM SP300VAC4000W-P
Power Analyzers RS HMC8015
Oscilloscopes Picoscope 4444, Siglent SDS2104X PLUS
Sound Analyzer Bruel & Kjaer 2270 G4
Microphone Bruel & Kjaer Type 4955-A
Temperature Logger Picoscope TC-08
Tachometer UNI-T UT372
Multimeters Keysight 34465A
UPS FSP Champ Tower 3kVA, CyberPower OLS3000E 3kVA
Isolation Transformer 4kVA
Testing Methodology Cybenetics PSU Test Protocol

Section B: ETA

Voltage115V230V
Efficiency (>1450 Load Combinations)0.000%82.963%
Efficiency Graphs
Average PF (>1450 Load Combinations)0.0000.973
Standby Power Consumption0.0000W0.0924W
ErP Lot 3/6 Ready
(EU) No 617/2013 Compliance
Average Efficiency VSB0.000%77.167%

Section C: LAMBDA

Voltage115V230V
Noise Rating (>1450 Load Combinations)0.00dBA44.57dBA
Noise Graphs

Section D: Information about DUT

Model NameCooler Master
Serial NumberMPX4001ACABW1164700477
CommentsNT 230V CL1 πάρθηκε με 2Α στα 12V Transient 20ms -> 20% τα 12V, 3.3V εκτός ορίων 10ms -> 20% τα 12V, 3.3V εκτός ορίων, 50% 5V εκτός ορίων OCP cold & hot 3.3V και 5V πάρθηκαν με 2Α στα 12V, στα 5VSB το PSU έκλεινε και έπρεπε να βγάλουμε-βάλουμε το καλώδιο του για να ξεκινήσει OCP cold & hot 5V έκλεισε κανονικά 12V δεν έκλεισε
Date of receiptNov 10, 2020
Testing DateNov 19, 2020
Report Issued DateNov 18, 2020
Engineer Name0
Authorized By the Laboratory General ManagerAristeidis Bitziopoulos

Section E: Deviation Additions, deviations, and exceptions to the method table

Uncertainty

The Noise Measurement’s Uncertainty is ±1.18 dB. The reported expanded uncertainty is based on a standard uncertainty multiplied by a coverage factor k=2, providing a level of confidence of approximately 95%.

The reported noise measurement’s level is the mean of 10 repeated measurements at an environment with a temperature deviation of ±2 degrees Celsius. The uncertainty was estimated according to the method in UKAS Publication M 3003.

Uncertainty Budget
Source of uncertainty Value ± Probability distribution Divisor Standard uncertainty
Calibrator’s calibration 0.2 dB Normal 2 0.1
Calibrator’s accuracy 0.2 dB Rectangular √3 0.058
Mic Frequency Response 2 dB Rectangular √3 0.577
Temperature Variation 0.04 dB Rectangular √3 0.012
Operator’s Accuracy 0.2 dB Rectangular √3 0.058
Standard uncertainty of mean of 10 repeated readings Normal 1 0.031
Combined Standard Uncertainty Assumed normal 0.59 dB
Expanded Uncertainty Assumed normal (k = 2) 1.18 dB

*Here the (±) half-width divided by √3 is used.