Customer: FSP Technology Inc.
NO.22,Jianguo E. Rd., Taoyuan Dist., Taoyuan City 330, Taiwan (R.O.C.)

Hydro PTM Pro 1200W

Report Number: 20PS1740A
Customer ID: 37

Test Report Results

Section A: Testing Equipment

Electronic Loads

Chroma 63601-5 x2
Chroma 63600-2
63640-80-80 x10
63610-80-20

AC Sources Chroma 6530, APM SP300VAC4000W-P
Power Analyzers RS HMC8015
Oscilloscopes Picoscope 4444, Siglent SDS2104X PLUS
Sound Analyzer Bruel & Kjaer 2270 G4
Microphone Bruel & Kjaer Type 4955-A
Temperature Logger Picoscope TC-08
Tachometer UNI-T UT372
Multimeters Keysight 34465A
UPS FSP Champ Tower 3kVA, CyberPower OLS3000E 3kVA
Isolation Transformer 4kVA
Testing Methodology Cybenetics PSU Test Protocol

Section B: ETA

Voltage115V230V
Efficiency (>1450 Load Combinations)89.959%92.029%
Efficiency Graphs
Average PF (>1450 Load Combinations)0.9900.958
Standby Power Consumption0.0753W0.2151W
ErP Lot 3/6 Ready
(EU) No 617/2013 Compliance
Average Efficiency VSB83.605%81.167%

Section C: LAMBDA

Voltage115V230V
Noise Rating (>1450 Load Combinations)26.91dBA25.71dBA
Noise Graphs

Section D: Information about DUT

Model NameFSP Technology Inc.
Serial NumberS0301000156
CommentsΝΤ 115V & 230V κλείνει στο Τ11, το πήρα με 106% 46 βαθμοί. CL2 100V, 115V & 230V κλείνει σχεδόν άμεσα δοκίμασα και με φορτία στα minor. OCP Hot κλείνει κατευθείαν στο CL2 δεν μπόρεσα να πάρω 12V hot, δοκίμασα με φορτία στα minor αλλά έκλεινε άμεσα.
Date of receiptOct 8, 2020
Testing DateOct 29, 2020
Report Issued DateOct 23, 2020
Engineer Name0
Authorized By the Laboratory General ManagerAristeidis Bitziopoulos

Section E: Deviation Additions, deviations, and exceptions to the method table

Uncertainty

The Noise Measurement’s Uncertainty is ±1.18 dB. The reported expanded uncertainty is based on a standard uncertainty multiplied by a coverage factor k=2, providing a level of confidence of approximately 95%.

The reported noise measurement’s level is the mean of 10 repeated measurements at an environment with a temperature deviation of ±2 degrees Celsius. The uncertainty was estimated according to the method in UKAS Publication M 3003.

Uncertainty Budget
Source of uncertainty Value ± Probability distribution Divisor Standard uncertainty
Calibrator’s calibration 0.2 dB Normal 2 0.1
Calibrator’s accuracy 0.2 dB Rectangular √3 0.058
Mic Frequency Response 2 dB Rectangular √3 0.577
Temperature Variation 0.04 dB Rectangular √3 0.012
Operator’s Accuracy 0.2 dB Rectangular √3 0.058
Standard uncertainty of mean of 10 repeated readings Normal 1 0.031
Combined Standard Uncertainty Assumed normal 0.59 dB
Expanded Uncertainty Assumed normal (k = 2) 1.18 dB

*Here the (±) half-width divided by √3 is used.